57
AGUADENS
COSMOGAS
8.5 - Condensate siphon
cleaning procedure
For correct cleaning of the collection siphon and the
conveying of the condensate produced by combustion,
operate as follows (refer to the figures 8-4, 8-5 and 8-6):
1.- with the appliance on, open a domestic hot water tap or
taps fully to force the burner to its maximum power and
the level of the liquid present inside the siphon tank “D”
lowers (see figure 8-5);
2.- switch off the appliance and disconnect the electrical
supply;
3.- access the internal components following section 8.2;
4 - remove the burner fan unit following section 8.3;
5 - cover the electric box with a cloth to protect it from any
residues of water inside the siphon to be removed.
6.- slide the support “B” outwards from the holding support;
7.- slide the tank “C” downwards, paying attention to the
fact that it is full of condensate water and this could
escape;
8.- extract the siphon outwards (see figure 8-5) paying
attention to disconnect the collection pipes of the water
coming from the upper part of the appliance and from the
air vent valve.
9.- clean the decanting tank “D”;
10.- re-mount everything in reverse order, paying attention
to the gasket “E”, which is put back in the relevant seat
and that terminal “G” is inserted correctly into seat “H”;
11.- restore the level of liquid inside the siphon following the
procedure in section 6.1.2.
Figure 8-5 - Removing condensate collection
siphon
Figure 8-6 - Condensate collection siphon
H
G
F
D
E
020002.01.030
8 - MAINTENANCE
Figure 8-4 - Removal of the condensate collection
siphon
B
C
A
B
C
A
020003.01.053
D
D
020003.01.054