52
AGUADENS
COSMOGAS
7 - USE
Err 122 Domestic hot water
outlet sensor (1002)
circuit open
Check that the electric resistance of the sensor
matches the graphics in section 8.14. Check the
electric cables for connection between the sensor
and the command board.
If the electric resistance does not match, replace it.
The electric circuit must be repaired if it is damaged.
Without either of the two previous cases, replace the
command and control board.
Err 123 Flue gas sensor (1006)
circuit open
Check that the electrical resistance of the sensor
matches the graphics in section 8.14
Check that the wires between the board and the
sensor are connected correctly
If the sensor does not match, the double exhaust
sensor must be replaced.
If the wires are not connected correctly, the connec
-
tions must be restored.
Err 124 Not applicable
(N/A)
(N/A)
Err 125 Not applicable
(N/A)
(N/A)
Err 126 Cold water inlet sensor
(1007) circuit, in short
circuit condition
Check that the electric resistance of the sensor
matches the graphics in section 8.14. Check the
electric cables for connection between the sensor
and the command board.
If the electric resistance does not match, replace it.
The electric circuit must be repaired if it is damaged.
Without either of the two previous cases, replace the
command and control board.
Err 127 Heat exchanger outlet
sensor (1001) circuit, in
short circuit condition
Check that the electric resistance of the sensor
matches the graphics in section 8.14. Check the
electric cables for connection between the sensor
and the command board.
If the electric resistance does not match, replace it.
The electric circuit must be repaired if it is damaged.
Without either of the two previous cases, replace the
command and control board.
Err 128 Heat exchanger outlet
sensor (1005) circuit, in
short circuit condition
Check that the electric resistance of the sensor
matches the graphics in section 8.14. Check the
electric cables for connection between the sensor
and the command board.
If the electric resistance does not match, replace it.
The electric circuit must be repaired if it is damaged.
Without either of the two previous cases, replace the
command and control board.
Err 129 Domestic hot water out
-
let sensor (1002) circuit,
in short circuit condition
Check that the electric resistance of the sensor
matches the graphics in section 8.14. Check the
electric cables for connection between the sensor
and the command board.
If the electric resistance does not match, replace it.
The electric circuit must be repaired if it is damaged.
Without either of the two previous cases, replace the
command and control board.
Err 130 Flue gas sensor (1006)
circuit in short circuit
condition
Check that the electrical resistance of the sensor
matches the graphics in section 8.14
Check that the wires between the board and the
sensor are connected correctly
If the sensor does not match, the double exhaust
sensor must be replaced
If the wires are not connected correctly, the connec
-
tions must be restored
Err 131 Not applicable
(N/A)
(N/A)
Err 132 External temperature
sensor circuit (1004) in
short circuit condition
(N/A)
(N/A)
(N/A)
Err 133 Not applicable
(N/A)
(N/A)
Err 134 Not applicable
(N/A)
(N/A)
Err 135 Phase neutral reversed
error
(N/A)
(N/A)
Err 200 Not applicable
(N/A)
(N/A)
Err 201 Not applicable
(N/A)
(N/A)
Err 202 Not applicable
(N/A)
(N/A)
Err 203 Too high difference
between supply and
return sensor
(N/A)
(N/A)
N/A = Not applicable
7.10 - Switch ON and OFF the appliance
To switch Off the appliance press in the same time the
and
keys and
On
will appear then press
key
and
OFF
will appear; Press RESET key to confirm the
OFF
state. To switch back ON the appliance press in the same time
the
and
keys and
OFF
will appear. Then
press
key and
On
will appear; press RESET key to
confirm the
On
state.
Содержание AGUADENS Series
Страница 65: ...65 AGUADENS COSMOGAS 8 MAINTENANCE ...
Страница 70: ......
Страница 71: ......
Страница 72: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com ...