48
AGUADENS
COSMOGAS
7 - USE
2024
Climatic adjustment: supply temperature corresponding to the
external spring-like temperature (N/A)
(N/A)
(N/A)
40
(N/A)
2027
Temperature reduction by room thermostat opening (N/A)
(N/A)
(N/A)
10
(N/A)
2040
Climatic adjustment: central heating boost temperature (N/A)
(N/A)
(N/A)
0
(N/A)
2041
Climatic adjustment: central heating boost time (N/A)
(N/A)
(N/A)
20
(N/A)
2042
Protection against frequent switch-on in central heating mode:
time (N/A)
(N/A)
(N/A)
180
(N/A)
2043
Protection against frequent switch-on in central heating mode:
temperature differential (N/A)
(N/A)
(N/A)
16
(N/A)
2060
Domestic hot water minimum power level
%
From 1 to 50
1
2061
Domestic hot water maximum power level
%
From 1 to 100
100
2062
Post-circulation in domestic hot water mode
sec
From 10 to 900
40
2063
Maximum time for loading storage tank (N/A)
(N/A)
(N/A)
60
(N/A)
2064
Number of flow meter revs. for every litre of water (N/A)
(N/A)
(N/A)
3,2
(N/A)
2066
Delay in the detection of the instantaneous domestic hot water
sec
From 1 to 10
1
2067
Storage tank loading procedure (N/A)
/
0 = (N/A);
1 = (N/A);
2 = ON, the domestic hot water
always has priority over heating;
2
2080
Periodic maintenance meter
(after RESET, the meter automatically goes back to ON)
/
ON = Periodic maintenance
meter active;
OFF = Periodic maintenance
meter off;
RESE = Meter reset
OFF
2081
Periodic maintenance meter: maintenance request time
days From 0 to 1000
1000
2100
Energy saving display
min
OFF = display always on
From 1 to 30 = delay to switch-
off in minutes.
5
7.9 - Diagnostics
During normal operation of the appliance, the visual display
in figure 7-1 continuously shows the state of work of the
appliance, via the following indications:
Parameter
Parameter Description
Display on visual display “H” in figure 7-1
AFro
Anti-freeze function active
Appliance temperature (°C)
Loc
Appliance blocked. To reset, press
RESET
. If the block occurs
frequently, contact a professionally qualified technician
Lockout code (see section 7.9.1 for decode)
Err
Appliance in error mode. Functioning can only be restored by
solving the cause of the anomaly. Contact a professionally
qualified technician
Error code (see section 7.9.2 for decode)
ALEg
Anti-legionella function running (see section 7.5).
It will end on reaching the water temperature of 60°C inside the
storage tank.
Storage tank temperature (°C)
SEr
Maintenance request for the appliance
Appliance temperature (°C)