Warranty
Table 4.6 Warranty (KLEA120F, KLNA120F)
Mounting
method
Cooling
method
Input
voltage
Average ambient
temperature (year)
Warranty term
Load factor
Io
[
75%
Load factor
75%<Io
[
100%
A
Convection
AC85 - 170V
Ta = 40
C
or less
5years
5years
Ta = 50
C
5years
3years
AC170 - 264V
Ta = 45
C
or less
5years
5years
Ta = 55
C
4years
3years
B
Convection
AC85 - 170V
Ta = 35
C
or less
5years
5years
Ta = 45
C
5years
3years
AC170 - 264V
Ta = 40
C
or less
5years
5years
Ta = 50
C
5years
4years
C
Convection
AC85 - 170V
Ta = 20
C
or less
5years
5years
Ta = 30
C
5years
5years
AC170 - 264V
Ta = 35
C
or less
5years
5years
Ta = 45
C
5years
4years
D and E Convection
AC85 - 170V
Ta = 15
C
or less
5years
5years
Ta = 25
C
5years
3years
AC170 - 264V
Ta = 30
C
or less
5years
5years
Ta = 40
C
5years
2years
A,B,C,D
and E
Forced air AC85 - 264V Ta = 70
C
5years
3years
Table 4.7 Warranty (
KLEA240F, KLNA240F)
Mounting
method
Cooling
method
Input
voltage
Average ambient
temperature (year)
Warranty term
Load factor
Io
[
75%
Load factor
75%<Io
[
100%
A
Convection
AC85 - 170V
Ta = 35
C
or less
5years
5years
Ta = 45
C
4years
2years
AC170 - 264V
Ta = 40
C
or less
5years
5years
Ta = 50
C
4years
3years
B
Convection
AC85 - 170V
Ta = 20
C
or less
5years
5years
Ta = 30
C
5years
2years
AC170 - 264V
Ta = 30
C
or less
5years
5years
Ta = 40
C
4years
2years
C
Convection
AC85 - 170V
Ta = 5
C
or less
5years
5years
Ta = 15
C
5years
5years
AC170 - 264V
Ta = 25
C
or less
5years
5years
Ta = 35
C
5years
3years
D and E Convection
AC85 - 170V
Ta = 0
C
or less
5years
5years
Ta = 10
C
5years
2years
AC170 - 264V
Ta = 15
C
or less
5years
5years
Ta = 25
C
4years
2years
A,B,C,D
and E
Forced air AC85 - 264V Ta = 70
C
5years
3years
4.6 Applicable Electric Cable
¡
Input terminals, Output terminals
Table 4.8 Applicable Wire
Input terminals
Output terminals
Solid wire
Diameter 0.5 mm to 2.6 mm (AWG.24 to AWG.10)
Stranded wire
0.2mm
2
to 5.2mm
2
(AWG.24 to AWG.10)
Conductor diameter more than 0.18mm
Sheath strip length
8mm
4.7 Applicable Electric Cable
¡
While turning on the electricity, and for a while after turning off,
please don’t touch the inside of a power supply because there are
some hot parts in that.
¡
When a mass capacitor is connected with the output terminal (load
side), the output might become the stop or an unstable operation.
Please contact us for details when you connect the capacitor.
5 Option
5.1 Outline of option
¿
-C
-
Option -C models have coated internal PCB for better moisture
resistance.
¿
-N2
-
Option -N2 models have attachment with screw mounting in-
stead of DIN rail mounting.
Mounting holes pitch are shown in Table 5.1.
Fig.5.1 Image of option -N2
4-
f
4.5
B
A
Fig.5.2 Mounting place (screw holes)
Table 5.1 Mounting holes pitch
No.
Model
A
B
1
KLEA120F, KLNA120F
24mm
133mm
2
KLEA240F, KLNA240F
34mm
133mm
AC-DC Power Supplies DIN Rail Type