1 Terminal Blocks

KL-8

2 Functions

KL-9

2.1  Input Voltage Range 
2.2  Inrush Current Limiting 
2.3  Overcurrent Protection  
2.4  Overvoltage Protection
2.5  Output Ripple and Ripple Noise
2.6  Output Voltage Adjustment Range
2.7 Isolation
2.8  Signal Output

3 Series/Parallel Operation

KL-10

4 Assembling and Installation Method

KL-10

KL-9
KL-9
KL-9
KL-9
KL-9
KL-9
KL-9
KL-9

3.1  Series Operation  
3.2  Parallel Operation  

4.1  Installation Mounting methods
4.2  Derating curve depend on input voltage
4.3  Derating curve depend on ambient temperature
4.4  Derating for low temperature start-up
4.5  Life Expectancy and Warranty
4.6  Applicable Electric Cable
4.7 Others

KL-10
KL-10

KL-10
KL-11
KL-11
KL-12
KL-12
KL-13
KL-13

5 Option

KL-13

5.1  Outline of option

KL-13

AC-DC Power Supplies DIN Rail Type

Instruction Manual

KL-7

Содержание KLEA120F

Страница 1: ...t method Switching frequency KLz Input current A 1 Rated input fuse Inrush current protection circuit PCB Pattern Series Parallel operation availability Material Single sided Double sided Series opera...

Страница 2: ...allation Method KL 10 KL 9 KL 9 KL 9 KL 9 KL 9 KL 9 KL 9 KL 9 3 1 Series Operation 3 2 Parallel Operation 4 1 Installation Mounting methods 4 2 Derating curve depend on input voltage 4 3 Derating curv...

Страница 3: ...40F KLNA120F Terminal Number Terminal Name Function 1 PE Protective earth Terminal 2 AC N Input Terminals 3 AC L 4 VOUT Output Terminals 5 VOUT Output Terminals 6 DC_OK LED for output voltage confirma...

Страница 4: ...LNA240F When the overcurrent protection circuit is activated and the output voltage drops to a certain extent the output becomes hiccup so that the average current will also decrease 2 Functions 2 4 O...

Страница 5: ...balance between the values of I1 and I2 Please make sure that the value of l3 does not exceed the rated current of a power supply l3 rated current value 4 Assembling and Installation Method 4 1 Insta...

Страница 6: ...ve depend on input voltage 4 3 Derating curve depend on ambient temperature The operative ambient temperature as different by input voltage Derating curve is shown below In the hatched area the specif...

Страница 7: ...ambient temperature year Life Expectancy Load factor Io 75 Load factor 75 Io 100 A Convection AC85 170V Ta 40C or less 10years or more 6years Ta 50C 5years 3years AC170 264V Ta 45C or less 9years 6ye...

Страница 8: ...5C or less 5years 5years Ta 15C 5years 5years AC170 264V Ta 25C or less 5years 5years Ta 35C 5years 3years D and E Convection AC85 170V Ta 0C or less 5years 5years Ta 10C 5years 2years AC170 264V Ta 1...

Отзывы: