3 Series/Parallel
Operation
3.1 Series Operation
¡
You can use a power supply in series operation. The output cur-
rent in series operation should be lower than the rated current of a
power supply with the lowest rated current among the power sup-
plies that are serially connected. Please make sure that no current
exceeding the rated current flows into a power supply.
Load
(a)
(b)
Load
Load
Power
Supply
+
-
Power
Supply
+
-
Power
Supply
+
-
+
-
Power
Supply
Fig.3.1 Examples of connecting in series operation
3.2 Parallel Operation
¡
There is no current balance function.
When operating in parallel, such as diode-OR, please use on the
output voltage was adjusted enough to balance the current.
Exceeds the rated output current, the output is shut down.
¡
Redundancy operation is available by wiring as shown below.
I
2
I
1
I
3
-
+
+
-
Load
Power
Supply
Power
Supply
Fig.3.2 Example of connecting in redundancy operation
Even a slight difference in output voltage can affect the balance
between the values of I
1
and I
2
.
Please make sure that the value of l
3
does not exceed the rated
current of a power supply.
l
3
[
rated current value
4 Assembling and
Installation Method
4.1 Installation Mounting methods
¡
About DIN-Rail
Attachment available with DIN EN60715 TH 35 (35×7.5mm or
35×15mm) (Top hat shaped DIN rail)
¡
Below shows mounting orientation.
If install other then standard mounting orientation (A), please fix
the power supply for withstand the impact and vibration.
(A) Standard
(B)
(C)
(D
(E)
)
DIN rail
OUTPUT
INPUT
OUTPUT
OUTPUT
INPUT
INPUT
OUTPUT
OUTPUT
INPU
IN
T
PUT
Fig.4.1 Mounting orientation
¡
When you mount a power supply on a DIN rail, have the area
marked A catch one side of the rail and push the unit to the direc-
tion of B. To remove the power supply from the rail, either push
down the area marked C or insert a tool such as driver to the area
marked D and pull the unit apart from the rail.
When you couldn’t remove the unit easily, push down the area
marked C while lightly pushing the unit to the direction of E.
A
B
D
C
E
Fig.4.2 Installation method
AC-DC Power Supplies DIN Rail Type
Instruction Manual
KL-10
KL-10