6.6 Heat sink(Optional parts)

¿

DHS50, DHS100

¡

The power module works with conduction cooling and needs heat 

dissipation using heat sinks. Optional heat sinks are available for 

DHS Series. Refer to Table 6.1 and Table 6.2 for details on the 

thermal resistance of heat sinks.

Table 6.1 Types of Heat Sinks Available

No.

Model

Size[mm]

Thermal resistance[

C

/W]

Style

H

W

D

Convection

(0.1m/s)

Forced Air

1

F-QB-F1 12.7 58.4 37.6

14.0

Refer Fig.6.5

Horizontal

2

F-QB-F2 12.7 58.7 37.3

Vertical

3

F-QB-F3 25.4 58.4 37.6

7.5

Horizontal

4

F-QB-F4 25.4 58.7 37.3

Vertical

5

F-QB-F5 38.1 58.4 37.6

5.0

Horizontal

6

F-QB-F6 38.1 58.7 37.3

Vertical

¡

It is necessary to note the thermal fatigue life by power cycle. 

Please reduce the temperature fl uctuation range as much as pos-

sible when the up and down of the temperature are frequently 

generated.

Contact us for more information on cooling methods.

¿

DHS50, DHS100

-40

-20

0

20

40

60

80

100 110

0

50

15

100

2

1

(85)

1

DHS100B24,28

2

Others

Aluminum base plate temperature Tc [

C

]

Load

factor

[%]

¿

DHS200

-40

-20

0

20

40

60

80

100 110

0

50

15

100

2

1

(85)

(75)

1

DHS200A05

2

Others

Aluminum base plate temperature Tc [

C

]

Load

factor

[%]

¿

DHS250

-40

-20

0

20

40

60

80

100 110

0

50

15

100

2

1

(85)

(75)

1

DHS250B12,48

2

Others

Aluminum base plate temperature Tc [

C

]

Load

factor

[%]

0

2

4

6

8

10

0.0

0.5

1.0

1.5

2.0

2.5

3.0

Wind velocity(m/s)

Thermal

resistance(

/w)

F-QB -F1/F2
F-

QB -F3/F4

F-QB -F5/F6

C

DC-DC Converters Bus Converter.Power Module Type

Instruction Manual

DHS-22

DHS

Fig.6.4 Heat Sink Types

W

D

D

H

H

W

Vertical

Horizontal

Fig.6.5 Thermal Resistance of Heat Sink(Forced Air)

Fig.6.3 Derating Curve

Tc
Measuring point

DHS50, DHS100

DHS200, DHS250

me̲dhs1.indd   DHS-22

me dhs1 indd DHS-22

2015/06/19   11:08:05

2015/06/19 11:08:05

Содержание DHS100A

Страница 1: ...For more information please contact FORTEC Elektronik AG Hauptniederlassung Lechwiesenstr 9 86899 Landsberg am Lech Telefon 49 0 8191 91172 0 Telefax 49 0 8191 21770 E Mail sales fortecag de Internet...

Страница 2: ...frequency kHz Input current A Rated input fuse PCB Pattern Series Parallel operation availability Material Single sided Double sided Series operation Parallel operation DHS50A DHS50B Forward converter...

Страница 3: ...ote sensing 4 6 Adjustable voltage range 4 7 Withstanding Voltage Isolation Voltage 5 Series and Parallel Operation DHS 20 5 1 Series operation 5 2 Redundancy operation 6 Implementation Mounting Metho...

Страница 4: ...ling capacitor 3 1 2 Noise filter Decoupling capacitor 3 Noise filter 4 Cin External capacitor on the input side 3 1 3 External capacitor on the input side 5 Co External capacitor on the output side 3...

Страница 5: ...itor Cin between VIN and VIN input pins within 50mm from pins DHS50B 100B more than 10 F DHS250B more than 22 F 4 Input voltage range Input current range The specification of input ripple voltage is s...

Страница 6: ...4 5 Remote sensing 1 When Remote Sensing is Not Used When remote sensing is not used make sure VOUT and S are shorted and that VOUT and S are shorted as well Keep the patterns between S and VOUT and b...

Страница 7: ...put voltage turn the potentiometer counter clockwise DHS200 DHS250 1 Output voltage adjusting Output voltage can be adjusted by connecting an external potenti ometer VR1 and resistors R1 and R2 as sho...

Страница 8: ...ting Method 4 7 Withstanding Voltage Isolation Voltage When testing the withstanding voltage make sure the voltage is increased gradually When turning off reduce the voltage gradual ly by using the di...

Страница 9: ...5deg temperature margin from the derat ing characteristic of Figure 6 3 6 2 Stress onto the pins Applying excessive stress to the input or output pins of the power module may damage internal connecti...

Страница 10: ...ture fluctuation range as much as pos sible when the up and down of the temperature are frequently generated Contact us for more information on cooling methods DHS50 DHS100 40 20 0 20 40 60 80 100 110...

Страница 11: ...nge The stress is accelerated by thermal cycling therefore the tem perature difference shoud be minimized as much as possible if temperature rise and down is occurred frequently Product lifetime expec...

Страница 12: ...k AG auptniederlassung echwiesenstr 9 6899 Landsberg am Lech elefon 49 0 8191 91172 0 elefax 49 0 8191 21770 Mail sales fortecag de nternet www fortecag de ik AG 40 54 80 56 11 40 54 80 56 13 ortecag...

Отзывы: