2  Configuration - Model 

Name Construction

  The AME series has Order Name which is used for the ordering 

aside from Model Name. Please contact us for the detail.

¡

Model Name Construction

AM

6

5

4

3

2

1

Code Code

1

2

3

4

5

6

Bar for Series

Bar for Parallel

Output modules

slot

1 2

3

4

5

 1

Model

    AM=AME series

 2

Power

    06=600W, 12=1200W

 3

Output module configuration

    The output module codes are showed in the specifications.
    When the slot is blank, “O” (Alphabet) needs to be set.
  

The number of slot is different depending on the model.

 4

Parallel code

    Refer to Table2.1 Parallel and Series Code.

 5

Series code

    Refer to Table2.1 Parallel and Series Code.

<Model Name Example>

AM12 ODCCBA

C

0004

Example of option
Parallel connection is not necessary.
Slot1  Module A  5V 12A
Slot2  Module B  12V 8.5A
Slot3, 4

Two Module C in series 

at 48V 5A
Slot5  Module D  48V 2.5A
Slot6 is blank
AME1200F

¡

Order Name Construction

 

1

 to 

3

 are same rules as Model Name, after that add manage-

ment number (6 digits).

  Parallel and series code are not listed on Order name.

<Order Name example>
  AM12 - O D C C B A - 

O

 

O

 

O

 

O

 

O

 

O

 

O

 : Alphanumeral 

 

O

 : management number (6digits)

¿

Note 

  (1)  Please select the output module codes from the specifications 

to correspond with required voltage and current.

     Please select ”O” when the slot is blank.
  (2)  If the output modules need to be connected in parallel or se-

ries, please select Parallel  or Series code from Table2.1.

  (3)  At least two slots have to be occupied.
  (4)  The following is the list of modules which can be used in series 

or parallel operation.

Available output modules

Series setting

A - D

Parallel setting

-

Table2.1  Parallel and Series Code.

Slot4

Slot5

Slot6

Slot3

Slot2

Slot1

00
01
02
03
04
05
06
07
08
09

0A

0B

0C
0D

0E

0F

10

11

12
13
14
15
16
17
18
19

1A

1B

1C
1D

1E

1F

Code

  : 

Output terminal

  : 

Connection

AME600F

AME1200F

AC-DC Power Supplies Configurable Type

Instruction Manual

AME-10

Содержание AME1200F

Страница 1: ...ility Material Single sided Double sided Series operation Parallel operation Input module of AME600F Active filter 67 Relay FR 4 Yes N A N A Half bridge converter 133 Input module of AME1200F Active f...

Страница 2: ...protection AME 12 4 6 Output ripple and ripple noise AME 12 4 7 Output voltage adjustment AME 12 4 8 Remote ON OFF RC AME 12 4 9 Global inhibit GI AME 12 4 10 Isolation AME 13 4 11 Alarm AME 13 4 12...

Страница 3: ...it ground 7 N C No connection 8 N C No connection 9 PR PR Alarm PRG 10 PRG PR Alarm ground Table 1 2 Pin configuration and function of CN2 Pin No Function Ground level 1 N C No connection 2 N C No con...

Страница 4: ...LV Alarm LVG 4 LVG LV Alarm ground 5 N C No connection 6 N C No connection 7 N C No connection 8 N C No connection 9 N C No connection 10 N C No connection Do not connect anything to N C pins Table 1...

Страница 5: ...V 2 5A Slot6 is blank AME1200F Order Name Construction 1 to 3 are same rules as Model Name after that add manage ment number 6 digits Parallel and series code are not listed on Order name Order Name e...

Страница 6: ...rush current limiting circuit If the interval of the input on off was short the inrush current limiting might not work correctly So please make its interval long enough And it makes the primary and th...

Страница 7: ...tion terminals Auxiliary power AUX for remote ON OFF The power supply has the auxiliary power AUX for the remote ON OFF The auxiliary power AUX is isolated from input output and FG Fig 4 3 is the exam...

Страница 8: ...the isolation test between the input and the output the input and the FG and the output and the FG is conducted all outputs and terminals for all functions should be shorted 4 11 Alarm The unit has t...

Страница 9: ...5 1 Installation method The unit has cooling fans Ensure that the inlet and outlet vents are not blocked Output module Air flow FAN Fig 5 1 Air flow Fig 5 2 is the recommended installation method whe...

Страница 10: ...0 1300 Input voltage VAC Total output power W 1200 85 90 150 170 264 900 Fig 5 7 Derating curve for input voltage AME1200F Defintion of load factor Load maximum value in A0 to A6 A0 100 Sum of each mo...

Страница 11: ...oltage Average ambient temperature yearly Warranty term 0 Io 75 75 Io 100 All mounting direction 85 to 170VAC Ta 40C or less 5 years 4 years Ta 50C 5 years 2 years 170 to 264VAC Ta 40C or less 5 years...

Отзывы: