1 Terminal Blocks

AME-8

3 Series / Parallel operation in Modular power supply

AME-11

3.1  Series operation  

 

AME-11

4 Functions

AME-11

5 Assembling and Installation Method

AME-14

4.1  Input voltage range  

 

AME-11

4.2  Inrush current limiting  

 

AME-11

4.3  Overcurrent protection  

 

AME-11

4.4  Thermal protection  

 

AME-11

4.5  Overvoltage protection  

 

AME-12

4.6  Output ripple and ripple noise  

 

AME-12

4.7  Output voltage adjustment  

 

AME-12

4.8  Remote ON/OFF (RC)  

 

AME-12

4.9  Global inhibit (GI)  

 

AME-12

4.10 Isolation 

 

 

AME-13

4.11 Alarm 

 

 

AME-13

4.12  Auxiliary power (AUX)  

 

AME-14

4.13  Medical Isolation grade  

 

AME-14

5.1  Installation method  

 

AME-14

5.2  Output side attaching externally capacitor  

 

AME-14

5.3   Derating  

 

AME-15

5.4  Life expectancy and Warranty  

 

AME-15

2 Configuration - Model Name Construction

AME-10

AC-DC Power Supplies Configurable Type

Instruction Manual

AME-7

Содержание AME1200F

Страница 1: ...ility Material Single sided Double sided Series operation Parallel operation Input module of AME600F Active filter 67 Relay FR 4 Yes N A N A Half bridge converter 133 Input module of AME1200F Active f...

Страница 2: ...protection AME 12 4 6 Output ripple and ripple noise AME 12 4 7 Output voltage adjustment AME 12 4 8 Remote ON OFF RC AME 12 4 9 Global inhibit GI AME 12 4 10 Isolation AME 13 4 11 Alarm AME 13 4 12...

Страница 3: ...it ground 7 N C No connection 8 N C No connection 9 PR PR Alarm PRG 10 PRG PR Alarm ground Table 1 2 Pin configuration and function of CN2 Pin No Function Ground level 1 N C No connection 2 N C No con...

Страница 4: ...LV Alarm LVG 4 LVG LV Alarm ground 5 N C No connection 6 N C No connection 7 N C No connection 8 N C No connection 9 N C No connection 10 N C No connection Do not connect anything to N C pins Table 1...

Страница 5: ...V 2 5A Slot6 is blank AME1200F Order Name Construction 1 to 3 are same rules as Model Name after that add manage ment number 6 digits Parallel and series code are not listed on Order name Order Name e...

Страница 6: ...rush current limiting circuit If the interval of the input on off was short the inrush current limiting might not work correctly So please make its interval long enough And it makes the primary and th...

Страница 7: ...tion terminals Auxiliary power AUX for remote ON OFF The power supply has the auxiliary power AUX for the remote ON OFF The auxiliary power AUX is isolated from input output and FG Fig 4 3 is the exam...

Страница 8: ...the isolation test between the input and the output the input and the FG and the output and the FG is conducted all outputs and terminals for all functions should be shorted 4 11 Alarm The unit has t...

Страница 9: ...5 1 Installation method The unit has cooling fans Ensure that the inlet and outlet vents are not blocked Output module Air flow FAN Fig 5 1 Air flow Fig 5 2 is the recommended installation method whe...

Страница 10: ...0 1300 Input voltage VAC Total output power W 1200 85 90 150 170 264 900 Fig 5 7 Derating curve for input voltage AME1200F Defintion of load factor Load maximum value in A0 to A6 A0 100 Sum of each mo...

Страница 11: ...oltage Average ambient temperature yearly Warranty term 0 Io 75 75 Io 100 All mounting direction 85 to 170VAC Ta 40C or less 5 years 4 years Ta 50C 5 years 2 years 170 to 264VAC Ta 40C or less 5 years...