11. MAINTENANCE
LThe OSMOTIC ZERO reverse osmosis equipment requires little maintenance:
Components such as the sediment pre-filter, activated carbon filter, reverse osmosis membrane and
remineralising post filter are subject to wear and have a limited duration. Their duration depends on local
circumstances, as the water of each region has its own composition. For your guidance, we show the duration
of the components mentioned:
• Sediment pre-filter: 12 months (depending on inlet water)
• Activated carbon filter: 12 months (depending on inlet water)
• Reverse osmosis membrane: 3 years (replacement of the first stage)
• Re-mineralising post-filter: 12 months
• UV lamp: 7000 hours
The duration of the elements shown is determined by certain parameters under laboratory conditions.
Excessive variation in these parameters could shorten the lifespan of these components, as could the use of
non-original spare parts and consumables.
To guarantee hygiene, the equipment needs to be sanitised on a regular basis, which involves cleaning the
elements that make up the filtering system.
Attention:
even when the tap is closed, the filter container vessels still contain a significant
amount of water. Have a container at hand when emptying it to avoid spilling water.
Note:
if you replace the pre-filter or the post-filter, it is not imperative to replace the rest. If you
replace the reverse osmosis membrane, then the sediment pre-filter, the activated carbon filter and
the re-mineralising post-filter should also be replaced.