Corsa OSMOTIC ZERO Скачать руководство пользователя страница 14

9. INSTALLATION

STEP 4

Install the 5-way valve into 
the cold water tube (between 
the house tap and the mains 
intake)

STEP 1

Drill a hole in the sink 
top using a 19mm bit.

STEP 2

Pass the tap 
through this hole.

STEP 3

Assemble the tap with the 
elements shown in the  
 

figure and in the  

 

same order.

STEP 6

Install the clamp for the equi-
pment drain outlet.

STEP 10

Connect the water outlet on 
the back of your equipment 
marked with to the tap of 
your Osmotic Zero  through 
the white 1/4 “pipe

STEP 8

Connect the water recovery 
(blue 5/16” pipe) to the 
5-way valve at the recovery 
outlet of the equipment 
marked with

STEP 9

Connect the drain to the sa-
fety outlet of your equipment 
marked with         through the 
red vinyl pipe

STEP 7

Connect the 5-way valve 
intake (blue 1/4” pipe) to the 
equipment inlet connector 
marked with

STEP 11

Make the plumbing connec-
tions to the equipment and 
afterwards connect it to the 
electricity supply.

STEP 5

Drill a hole in the sink drain 
with a 7.2 mm bit.

The cabling used for the electronic circuit must be supplied by the manufacturer. Under no circumstances 
may extensions be used.

14

Содержание OSMOTIC ZERO

Страница 1: ...INSTRUCTION MANUAL...

Страница 2: ...ing OSMOTIC ZERO you ensure perfect water for drinking and cooking OSMOTIC ZERO uses only physical processes to achieve the desired water purity this consists of segrega ting out all the undesired ele...

Страница 3: ...t 9 4 Installation accessories 10 5 Technical specifications 6 Main functions 11 7 Hydraulic diagram 12 8 Pilot lights and alarms 13 9 Installation 14 10 Use of the equipment 15 11 Maintenance 16 12 S...

Страница 4: ...s Do not disassemble or modify this equipment yourself Manipulate the equipment solely to change consumables Unauthorised disassembly or modification of the equipment can lead to malfunction or water...

Страница 5: ...ltraviolet light emitted may cause annoyance or damage to the skin and eyes Do not place the equipment near heat sources Do not place the equipment near a heat source or where the temperature is exces...

Страница 6: ...ng of the equipment Do not use this equipment outdoors If the equipment is used outdoors there may be accelerated ageing of equipment pipes and parts which could cause leakage or machine malfunction E...

Страница 7: ...or to ensure proper operation Leak and moisture sensor Water evacuation pipe in case of emergency 2 Stable water flow The equipment has a filtration system capable of producing up to 38 l h at 3 5 bar...

Страница 8: ...nnecting and disconnecting the elements necessary merely by opening the tap 9 Operating pressure The equipment allows inlet working pressures of 1 5 to 5 5 bars 8 GPRS connection You can connect via G...

Страница 9: ...PARTS OF THE EQUIPMENT Side slits for opening Permeate water produced WHITE 5 16 Water inlet BLUE 1 4 Pressure transducer coupling Power supply Reject drain RED 1 4 Water recovery BLUE 5 16 Tap coupl...

Страница 10: ...ite pipe 5 16 2m blue pipe 1 4 2m red pipe 2m blue pipe 5 16 6 2 Drain clamp 6 3 5 way 3 8 inlet valve 6 4 Pressure transducer Supply Power consumption Inlet water pressure Inlet temperature Maximum T...

Страница 11: ...This renders the water hygienic using ultraviolet light It does not add any chemicals odour or taste to the treated water The OSMOTIC ZERO water filtering process consists of 2 The second stage is an...

Страница 12: ...9 A 150 GPD membrane 9 B 150 GPD membrane 10 Re mineralising post filter 11 Permeate tank level gauge 12 4 W external ultraviolet lamp 13 Permeate water 4 L capacity accumulation tank 14 Permeate pump...

Страница 13: ...tio Contact technical service to change filters Attention Water tank empty Wait until full Attention Close the Osmotic Zero inlet tap Contact technical service Attention Close the Osmotic Zero inlet t...

Страница 14: ...Zero through the white 1 4 pipe STEP 8 Connect the water recovery blue 5 16 pipe to the 5 way valve at the recovery outlet of the equipment marked with STEP 9 Connect the drain to the sa fety outlet...

Страница 15: ...t This is activated when the tank level gauge is at a minimum level or when we actuate the tap B The water enters the filter assembly sediment activated carbon and osmosis membrane No 1 C The residual...

Страница 16: ...mp 7000 hours The duration of the elements shown is determined by certain parameters under laboratory conditions Excessive variation in these parameters could shorten the lifespan of these components...

Страница 17: ...or absorbent material on the bottom of the filter to be changed figure 3 to retain the possible remaining water when it is removed Then the quick connect pipe must be disconnected by pressing the clam...

Страница 18: ...sition indicated on its base figure 9 and then turn it clockwise using the key until the symbol on the base of the filter reaches position 2 figure 10 Connect the connection tubes to the quick link fi...

Страница 19: ...TER SPARE PART Disconnect the connecting pipes by pressing the quick link clamp figure 12 and replace the post filter figure 13 5 CLOSING Poser les couvercles lat raux dans les clips figure 14 Figure...

Страница 20: ...cal service A Check the mains pressure B Contact the authorised technical service SOLUTION A Defective outlet pump B Inlet valve partially blocked A Lack of water B Inlet valve closed C Membrane satur...

Страница 21: ...indicated test conditions the aforementioned production and conversion cannot be guaranteed The conditions that could modify the production and conversion would be Higher or lower temperature Greater...

Страница 22: ...THE WATER REVOLUTION...

Отзывы: