- 19 -
COROB EVOFLX-LW
6
START-UP
6.1
General warnings
Personnel in charge of these operations must wear the following personal
protective equipment.
6.2
Management computer
The dispenser is fully managed by a normal personal computer that can be provided upon request, since it is not
supplied as standard together with the machine. The manufacturer can also supply a wide range of software
applications to manage all of the machine’s functions.
The complete installation of the machine, including computer connection, management software installation and
system configuration, must be carried out by a specialized maintenance technician.
6.3
Control devices and connections
1.
Machine main switch
2.
Fuse compartment
- The value of fuses is shown in the technical specifications table (chapter 9.1).
3.
Main plug
4.
Auxiliary sockets
(optional) - Power supply to the computer and other equipment (calibration scale or label
printer)
5.
USB serial port
- For the connection to the management computer.
6.
Control panel
- With the off-line button and the signal lamps.
7.
Buttons to move the shelf
(two-handed control).
DANGER
THIS EQUIPMENT MUST BE GROUNDED. Check the grounding of the power supply system before connecting
the machine.
Do not use extension cords to power the machine.
The computer and any other devices connected to the machine via a serial line or connected to the computer itself
must be powered by an equipotential power supply network or, if present, by the auxiliary sockets (optional).
Do not connect devices other than computer, label printer or calibration scale to the auxiliary sockets.
Do not use multisockets to connect other equipment to the same socket that powers the machine
.
WARNING
Do not attempt to power the machine from a source having specifications other than those listed on the
identification plate.
The machine is isolated from the power supply line when the power plug is disconnected; it must therefore be
installed near an easily accessible mains socket outlet.
The power supply of the equipment connected to the machine via serial port, like the computer, must be
equipotential (which has a single access point to earth) because potential differences cause interferences and/or
damage to the serial ports
.
Содержание EVOFLX-LW
Страница 1: ...EVOFLX LW User manual V1 0 RB 2019...
Страница 30: ...COROB EVOFLX LW 28...
Страница 35: ...33 COROB EVOFLX LW...
Страница 36: ...COROB EVOFLX LW 34...
Страница 42: ...COROB EVOFLX LW 40 APPENDIX EC DECLARATION F A C S I M I L E...
Страница 43: ...41 COROB EVOFLX LW F A C S I M I L E...
Страница 44: ......
Страница 45: ......