Xtreme Ice Training Manual
TP00952
October 17, 2005
18
LED INDICATORS
The LEDs are board circuit indicators. If the LED in the functional board circuit is complete, check component.
Example: Contactor does not energize and LED is “ON”, board circuit is OK. Check contactor, coil, leads,
& connections.
Yellow:
S
Evaporator switch(s) (proximity)
S
Delay (located on the electrical box front).
Green:
S
Water dump valve
S
Compressor contactor
S
Water Pump
S
Hot Gas Valve
S
Condenser Fan (cycles on & off with fan)
S
Fill Valve
Red:
S
Error (located on the electrical box front).
S
Ice thickness Adjustment.
Refer to flash codes for control and system diagnostics. Add the flash codes before status indicators (See Figure
11).
Error LED
Delay LED
Red
Yellow
FIGURE 11
STATUS INDICATOR
Green LED
Condenser Fan
Yellow LED
Left Water Curtain
Green LED
Hot Gas Valve
Green LED
Water Pump
Yellow LED
Right Water Curtain
Green LED
Compressor Contactor
Red LED
Error
Green LED
Dump Valve
Green LED
Fill Valve
Yellow LED
Delay
Red LED
Ice Thickness Adjustment
Содержание XAC 1030 E50
Страница 2: ......