Xtreme Ice Training Manual
TP00952
October 17, 2005
43
XTREME ICE – KITS
BIN STAT KIT, P/N 630000408
Installation Instructions
These Bin Stat kits apply to all “X” Series Ice makers.
Loose–Shipped Parts
Item No.
Part No.
Name
Qty.
1
630000837
Thermostat Asy
1
2
07578
Screw TC 08–32
2
3
630460162
Installation Instruction, Thermostat
1
4
630900895
Hex Nut 8–32 SS Keps
2
5
620045454 or
620045455 or
620045456 or
620045457
Bin Stat Support
1
1. Disconnect power.
2. Remove front cover of the unit and the electrical box cover plate. For 22” wide units you will need to
remove the Grill from the right side of the unit.
3. To mount bin thermostat in electrical box:
A.
Route wires and connector through grommet in electrical box (see Figure 18).
B.
Attach bin thermostat to electrical box with two 08–32 TC screws provided (see Figure 18).
4. Connect the bin thermostat lead to the circuit board (see Figure 19).
5. Straighten approximately 12” of capillary tube to go through hole in chassis base. Re–coil the re-
mainder. Do not disturb the tightly coiled end.
6. Insert the “1/4” diameter wire Bin Stat support into the coiled end of capillary tube. Carefully wrap 5
turns of free capillary tube tightly around the Bin Stat support. Insert the assembly through the hole
in the chassis base. Route capillary tube to follow the Bin Stat support as closely as possible (see
Figure 20).
7. Slip eye of Bin Stat support over the 8–32 weld stud in the chassis base. If a nut exists on this weld
stud remove before assembling the Bin Stat support. Secure the Bin Stat support with the 8–32
Keps nut provided in the kit (see Figure 20).
8. Any excess capillary tubing must be carefully pulled back into the compressor compartment to pre-
vent ice from damaging it during dispenser operation.
9. Seal
½
” diameter hole with sealant (RTV).
10. Turn bin stat adjustment screw clockwise until it stops. Then turn it counterclockwise 1/8 of a turn.
11. Reinstall the front cover of the electrical box and the ice machine and reconnect the power. Verify
that the Bin Stat is working by holding ice on the coiled bare capillary tube. The bin stat will allow the
ice machine cycle to complete and harvest ice. Then the ice machine will shut down. Remove the ice
from the capillary tube and warm the tube with hand heat. The ice machine should start in approxi-
mately 60 seconds. Reinstall front cover and grill (22” units only).