To Replace Bearing   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16

Electrical Checkout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16

Overload Check   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16

Compressor Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

Capacitor Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

Safety Controls  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

Guide to Good Ice  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18

Содержание WCC1401-A Series

Страница 1: ...R WCC1401 A WCF1411 A Series Service Manual Release Date October 26 2006 Publication Number 630460324SER Revision Date March 18 2014 Revision E Visit the Cornelius web site at www cornelius com for al...

Страница 2: ...ccurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Product 2 improper voltage 3 inadequate wiring 4 abuse 5 accident 6 alterat...

Страница 3: ...ning and Sanitizing Procedures 8 Maintenance 8 Monthly 8 Quarterly 8 Semi Annually 9 Refrigeration System 10 Temperature Pressure Charts 10 Refrigeration System Adjustments 10 Pump down Cycle 10 Expan...

Страница 4: ...To Replace Bearing 16 Electrical Checkout 16 Overload Check 16 Compressor Check 17 Capacitor Check 17 Safety Controls 17 Guide to Good Ice 18...

Страница 5: ...oderate injury or equipment damage SAFETY TIPS Carefullyreadandfollowall safety messages inthismanualandsafety signsontheunit Keepsafety signsin goodconditionandreplace missingordamageditems Learnhowt...

Страница 6: ...y or equipment damage SHIPPING AND STORAGE CAUTION Before shipping storing or relocating the unit the unit must be sanitized and all sanitizing solution must be drained from the system A freezing ambi...

Страница 7: ...ORMATION This section gives the Unit description theory of operation and design data for continuous flow icemaker series WCC1401 A SPECIFICATION CHART Models Description VAC HZ PH Wire Comp RLA Fan Am...

Страница 8: ...Continuous Flow Icemaker Service Manual Publication Number 630460324SER 4 2006 2014 Cornelius Inc Figure 1 Series WCC1401 A WCF1411 A Dimension Drawing...

Страница 9: ...Continuous Flow Icemaker Service Manual 2006 2014 Cornelius Inc 5 Publication Number 630460324SER ELECTRICAL Figure 2 Schematic WCC1401 A WCF1411 A...

Страница 10: ...Continuous Flow Icemaker Service Manual Publication Number 630460324SER 6 2006 2014 Cornelius Inc REFRIGERATION SCHEMATIC Figure 3 WCC1401 A...

Страница 11: ...Continuous Flow Icemaker Service Manual 2006 2014 Cornelius Inc 7 Publication Number 630460324SER Figure 4 WCC2001QTR Refrigeration Diagram...

Страница 12: ...erature water 2 minute exposure time 10 Sanitize auger diverter assembly and ice transition drop tube in a sink using sanitizing solution and reinstall in icemaker Using sanitizer wipe down the dispen...

Страница 13: ...icemaker water seal 2 Check drain tubes for clogs and aged tubes Replace if tubes are stained or brittle 3 Check for signs of condensation Clean where necessary and replace insulation properly 4 Check...

Страница 14: ...blies and a liquid line solenoid The condensing unit consists of a compressor condenser fan motor and receiver The icemaker is designed for indoor use only The condensing unit is designed for outdoor...

Страница 15: ...l in icemaker has again been reached 3 The transparent bowl not only provides a visible check of water level but also is a good guide to the internal conditions which exist within the icemaker assembl...

Страница 16: ...cated on the top of the dispense tray cover When replacing the sensor make sure the bulb is inserted to the bottom of the thermostat well GEAR MOTOR The gear motors are equipped with a start relay and...

Страница 17: ...Continuous Flow Icemaker Service Manual 2006 2014 Cornelius Inc 13 Publication Number 630460324SER...

Страница 18: ...ntinuity replace the relay Figure 6 Gearmotor Assembly TO REPLACE GEARMOTOR ASSEMBLY WARNING Disconnect power to the unit before servicing Follow all lock out tag out procedures established by the use...

Страница 19: ...he output shaft drive and the extruding head ribs engage the evaporator tube INSTALLATION AND SHAFT SEAL REPLACEMENT 1 Place shaft seal locator seat and shaft seal mount over gearmotor output shaft an...

Страница 20: ...2 Remove Dispense Tray Cover 3 Use an open end wrench on auger nut connected to bearing and turn counterclockwise to remove assembly 4 Remove worn bearings Replace with new bearings and then reinstall...

Страница 21: ...ead or connections if there is no continuity CAPACITOR CHECK 1 Check or replace start capacitor disconnect bleed resistor before checking for shorted capacitor 2 Check or replace run capacitor if supp...

Страница 22: ...Continuous Flow Icemaker Service Manual Publication Number 630460324SER 18 2006 2014 Cornelius Inc GUIDE TO GOOD ICE...

Страница 23: ...Figure 12 Troubleshooting Chart Continuous Flow Icemaker Service Manual 2006 2014 Cornelius Inc 19 Publication Number 630460324SER...

Страница 24: ...Continuous Flow Icemaker Service Manual Publication Number 630460324SER 20 2006 2014 Cornelius Inc...

Страница 25: ......

Страница 26: ...Cornelius Inc www cornelius com...

Отзывы: