Continuous Flow Icemaker Service Manual
© 2006-2014 Cornelius Inc.
- 11 -
Publication Number: 630460324SER
WATER LEVEL CONTROL
H
OW
W
ATER
L
EVEL
C
ONTROL
W
ORKS
When water is introduced through the inlet fitting the float rises, the float pushes against a lever that in turn, forces
the poppet assembly against the inlet fitting valve seat that seals the water off. See Figure 1 (page 7). Before the
water inlet is sealed, the safety switch is operated. In the event of a water failure the float would drop down and
operate the safety switch to shut off the machine.
If water level control will not shut off and seal at level as indicated, be sure inlet pressure does not exceed
recommended factory operating range.
Under ordinary circumstances adjustment should not be necessary providing it was properly adjusted when unit
was installed or relocated. If however, the control becomes inoperative, repair or replace. See Start-up Adjustment
in the installation manual.
P
URPOSE
OF
W
ATER
L
EVEL
C
ONTROL
1.
To automatically maintain proper water level in the evaporator when the unit is running and making ice.
2.
A safety switch is operated in the event of an interruption in water supply. The switch shuts off the electrical
power to the icemaker and its refrigeration system. Switch will reset as soon as cause of water failure has been
corrected and proper water level in icemaker has again been reached.
3.
The transparent bowl not only provides a visible check of water level, but also is a good guide to the internal
conditions which exist within the icemaker assembly itself. (See cleaning procedure.)
T
O
R
EPLACE
W
ATER
L
EVEL
C
ONTROL
!
WARNING
:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1.
Shut off the water supply. Shut off the main power switch or unplug the ice dispenser from electrical outlet.
2.
Remove the flexible tubing from bottom of water level control and drain water from water level control and evap-
orator.
3.
Remove flexible tubing at bottom of water level bowl connected to the overflow.
4.
Hold water inlet fitting with proper tool to prevent it from rotating when disconnecting the water inlet.
5.
Remove wing nut holding water control to its mounting bracket. Control can be removed by lifting straight up.
T
O
R
EPLACE
W
ATER
L
EVEL
S
AFETY
S
WITCH
!
WARNING
:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1.
Unplug Molex connector connecting switch to electrical box.
2.
Remove the 2 screws anchoring the water level safety switch to the bottom of the water level control mounting
bracket.