Continuous Flow Icemaker Service Manual
© 2006-2014 Cornelius Inc.
- 15 -
Publication Number: 630460324SER
Figure 7. Auger and Extruding Head Removal
A
UGER
AND
E
XTRUDING
H
EAD
R
EMOVAL
!
WARNING
:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1.
Remove storage container cover and put aside.
2.
Turn off water supply to icemaker.
3.
After ice has melted from head take hold of the auger nut and lift straight up to disengage from icemaker.
4.
When replacing the auger assembly, make certain that both the auger engages the output shaft drive and the
extruding head ribs engage the evaporator tube.
I
NSTALLATION
AND
S
HAFT
S
EAL
R
EPLACEMENT
1.
Place shaft seal locator seat and shaft seal mount over
gearmotor output shaft and push down until shaft seal seat
and shaft seal mount rest flush on top of gearmotor.
2.
Place rubber coated ceramic seal (important: ceramic face
up) over output shaft and push down until seal nest in
recess of shaft seal mount. (lubricate rubber on ceramic
seal with rubber lubricant).
3.
Place shaft seal with carbon face down (spring up) over
output shaft and push (gently) downward until seal rests on
carbon face of the output shaft seal.
4.
Place flat washer over output shaft and let rest on the out-
put shaft seal. Push down on the washer compressing the
spring on the output shaft seal. While holding the seals
(down) in place slide the E–ring into the groove on the out-
put shaft
Figure 8. Shaft Seal 700 and 1000
Содержание WCC1401-A Series
Страница 17: ...Continuous Flow Icemaker Service Manual 2006 2014 Cornelius Inc 13 Publication Number 630460324SER...
Страница 24: ...Continuous Flow Icemaker Service Manual Publication Number 630460324SER 20 2006 2014 Cornelius Inc...
Страница 25: ......
Страница 26: ...Cornelius Inc www cornelius com...