![Cornelius WCC1401-A Series Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/cornelius/wcc1401-a-series/wcc1401-a-series_service-manual_2668276018.webp)
Continuous Flow Icemaker Service Manual
Publication Number: 630460324SER
- 14 -
© 2006-2014 Cornelius Inc.
M
OTOR
C
HECK
The resistance readings on the winding will be between 5 to 25 ohms. A meter capable of these low readings must
be used. The start relay cover must be removed.
If no continuity on start or run winding test, replace gearmotor. If continuity on grounded motor test, replace
gearmotor.
S
TART
R
ELAY
1.
Check between “2” and “4” on relay (with relay unplugged). If there is continuity replace the relay, as the relay
contacts should be open.
2.
Check between “3” and “4” on relay, if no continuity replace the relay.
Figure 6. Gearmotor Assembly
T
O
R
EPLACE
G
EARMOTOR
A
SSEMBLY
!
WARNING
:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1.
Disconnect the transmission cable from the electrical box.
2.
Remove the 4 hex head bolts securing the evaporator to the top of the transmission.
3.
Remove the 4 bolt’s holding the transmission and bracket to frame base, while supporting the weight of the
evaporator. Remove the transmission from the unit.
4.
When replacing the transmission, it may be necessary to rotate the auger back and forth to align the motor
shaft and auger.
Содержание WCC1401-A Series
Страница 17: ...Continuous Flow Icemaker Service Manual 2006 2014 Cornelius Inc 13 Publication Number 630460324SER...
Страница 24: ...Continuous Flow Icemaker Service Manual Publication Number 630460324SER 20 2006 2014 Cornelius Inc...
Страница 25: ......
Страница 26: ...Cornelius Inc www cornelius com...