![Cornelius VIPER E Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/cornelius/viper-e/viper-e_service-manual_2667946037.webp)
Viper Low overrun Service Manual
© 2016, Cornelius Inc
- 31 -
Publication Number: 621360241LOEWSE
Motor Setup Menu
Motor setup is initially done at the factory and does not need to be changed unless a barrel motor or barrel compo-
nents are replaced, adjusted or removed and reinstalled.
This menu allows you to select different motor types for each barrel in the unit and run the calibration procedure on
that motor. This procedure correlates the actual viscosity of the barrel and its contents with the electrical character-
istics of the motor. These characteristics are stored by the control system and are accessed at the time of calibra-
tion for each particular motor.
Because of the differences between motor characteristics from different motor suppliers, the Motor menu, shown in
Figure 28, is used to adjust the unit settings to match the motor type being installed. It provides the correct table of
electrical characteristics from embedded settings located in non-volatile memory. Perform the procedure described
in Table 30 to change the motor type setting. Insure that the motor type matches the settings listed in Table 28
based on model.
NOTE: If the Motor Type shown is “DEFAULT”, it indicates that the EEPROM is not installed or is faulty.
Figure 28. Motor Setup Screen
Table 28.
Model
Motor Type
All 60 Hz
1
All 50 Hz
2
Table 29.
Button
Description
BACK
Returns the display to the Select menu
CAL
Verifies the motor settings of a new motor.
-
Decrements the highlighted field
+
Increments the highlighted field
Table 30.
Step
Action
Procedure
1
Set barrel for Motor Type
From the Maintenance menu (Figure 20), open the
Motor Setup menu, shown in Figure 28.
2
Select the barrel
Use the Up and Down arrows to highlight the desired
barrel
3
Select the proper motor
type
Press the + or - buttons at the bottom of the display to
select the proper motor type
4
Complete the procedure
Press the BACK button at the bottom of the display to
save the settings and return to the Setup menu.
MOTOR
SETUP
12:51P
MAR 04
#1 MOTOR TYPE 1
#2 MOTOR TYPE 2
BACK CAL - +