Figure 36. Side View of Seal and Spacer on Motor Shaft
M
OTOR
S
EAL
L
EAK
T
EST
After replacing the motor seal, it is advisable to test the seal under pressure before refilling the barrel with product.
Perform the procedure in Table 47 to verify that the seal is installed properly and not leaking. When the seal passes
the leak test, perform the motor calibration routine on page 32.
B
ARREL
M
OTOR
R
EPLACEMENT
The barrel motor does not require any special alignment when being replaced. It mounts on four (4) bolts. These
bolts are screwed into threaded bosses in the foam pack barrel assembly, as shown in Figure 37. To replace a bar-
rel motor, perform the procedure in Table 48.
Table 47.
Step
Action
1
Turn the 3-way Product Supply valve behind the splash panel (see Figure 26)
to the Off (horizontal) position.
2
From the Maintenance menu, press the FILL button for the barrel. This pres-
surizes the barrel with CO
2
.
3
Observe the water and syrup fill solenoids.
4
If there are NO seal leaks, these solenoids cycle off within a minute and
remain off.
5
If the solenoids cycle off and remain off, the barrel seal is not leaking and the
barrel is ready to be filled with product.
6
If the solenoids do not cycle off, or cycle off and on, the seal is leaking and the
seal installation process described in Table 45 and Table 46 must be repeated.
7
If there are no leaks, turn the 3-way Product Supply valve to the BRIX position.
Seal