UC 700 Series Continus-Flow Icemaker Installation/Service Manual
Publication Number: 630460127
- 22 -
© 2000-2011, IMI Cornelius Inc.
C
APACITOR
C
HECK
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1.
Check or replace start capacitor, disconnect bleed resistor before checking for shorted capacitor.
2.
Check or replace run capacitor (if supplied) check for shorted capacitor or either terminal grounded to
case.
Figure 12. Gear Motor Overload
S
AFETY
C
ONTROLS
Your icemaker unit has several safety and control devices incorporated into its design.
!
WARNING:
None of the below described devices should ever be “bypassed” to allow the unit to function.
Failure to comply could result in serious injury, death or damage to the equipment.
The safety and control system shut-off devices are:
1.
Low water shut off reed switch located in icemaker float assembly. (Automatic reset type.) (See Figure 3.)
2.
Gearmotor thermal overload, manual reset type (red button on motor). See Wiring Diagram Figure 14.
3.
Compressor thermal overload, automatic reset type. See Figure 10.
4.
Anti-freeze relay and associated circuit. See Wiring Diagram Figure 14.
5.
Main service switch located on top of the control box. See Wiring diagram Figure 14.
6.
Bin Control.
7.
High pressure cut out (water cooled only).
WARNING
DO
NOT
PRESS
RESET
IF
REFRIG
UNIT
IS
RUNNING
OR
ICE
MAKER
IS
FROZEN