UC 700 Series Continus-Flow Icemaker Installation/Service Manual
© 2000-2011, IMI Cornelius Inc.
- 19 -
Publication Number: 630460127
A
UGER
AND
E
XTRUDING
H
EAD
R
EMOVAL
1.
Disconnect unit from power supply.
2.
Remove storage container cover and put aside.
3.
Turn off water supply to icemaker.
4.
After ice has melted from head take hold of the auger nut and lift straight up to disengage from icemaker.
5.
When replacing the auger assembly, make certain that both the auger engages the output shaft drive and
the extruding head ribs engage the evaporator tube. (See Figure 8.)
Figure 9. Shaft Seal
I
NSTALLATION
AND
S
HAFT
S
EAL
R
EPLACEMENT
(S
EE
F
IGURE
9.)
1.
Place shaft seal locator seat and shaft seal mount over gearmotor output shaft and push down until shaft
seal seat and shaft seal mount rest flush on top of gearmotor.
2.
Place rubber coated ceramic seal (important: ceramic face up) over output shaft and push down until seal
nest in recess of shaft seal mount. (lubricate rubber on ceramic seal with rubber lubricant).
3.
Place shaft seal with carbon face down (spring up) over output shaft and push (gently) downward until seal
rests on carbon face of the output shaft seal.
4.
Place flat washer over output shaft and let rest on the output shaft seal. Push down on the washer com-
pressing the spring on the output shaft seal. While holding the seals (down) in place slide the E-ring into
the groove on the output shaft.