Triton R134a Range
Manual operation undercounter cooler
Triton R134a Range
Page 10
Cornelius Deutschland GmbH
Document no: TD1014600EN
Version A, 24.09.2019, Index 0
5
Putting into and out of Service (To be done only by « operator »)
5.1
Putting into Service
Comply with the cleaning regulations defined by law before beginning each operation.
Clean the couplings on the container for beverage/syrup every time before you attach them. Connect coupling
to container for beverage/syrup. Note: Gray = CO
2
, black = beverage/syrup.
Open the cylinder valve on the CO
2
-cylinder and the valve on the pressure regulator. Check the CO
2
-pressure
at the pressure regulator. It should be within the following standard values
Syrup (sugar based):
0.40 to 0.45 MPa (4.0 to 4.5 bar)
CO
2
-carbonization pressure:
0.52 to 0.58 MPa (5.2 to 5.8 bar)
Syrup Light product:
0.21 to 0.28 MPa (2.1 to 2.8 bar)
Drinking water:
0.35 to 0.45 MPa (3.5 to 4.5 bar)
Set the CO
2
-pressure by turning the control screw at the regulator valve.
Clockwise to increase the pressure.
Counter-clockwise to reduce the pressure.
Afterwards check the CO
2
-lines for leaks by closing the valve of bottle. The set pressure displayed at the
pressure regulator should not drop. If it does, notify the service technician immediately. Do not forget to re-
open the CO
2
-valve after the check.
Open the water feed line and check the flow pressure in it (minimum value: 0.2 to 0.3 MPa (2.0 to 3.0 bar)).
Set it at the control screw on the water pressure regulator (not contain in the supply schedule).
Check the beverage/syrup lines for leaks. Only a visual inspection is possible. If liquid is leaking, call a service
technician.
5.2
Turning on the Unit
(To be done only by « expert »)
The water bath must be filled up to ca. 1 cm under the overflow with tap water. Refer to the technical data for
the amount required. To prevent algae from forming in the water, add the disinfectant Molco (PN 14-9670-
150). The 150 ml container of disinfectant is sufficient for 30 liters of water.
Insert the mains plug for the cooler into a socket outlet with a grounding contact.
Ice bank controlled units start working after the water bath fills with water and switch off automatically after the
ice bank is built up. The control board of the unit has a time delay for switching on and off the cooling system,
when it runs in ice bank mode. After the cooling system is switched on the running time is not less than 5
minutes. Switch off signals will be ignored during this time. After the cooling system is switched off the break
time is not less than 3 minutes. Switch on signals will be ignored during this time. The break time of 3 minutes
is valid for turning on the device and after a breakdown of the power supply.
This unit contains a 3-pin ice bank probe. Take care that the probe is always correctly adjusted. Wrongly
adjusted probes can be adjusted by using the adjusting device 22-0055-X99 or by using the data shown in
paragraph 12.
The agitator motor is a closed version.
Attention!
Temperatures up to 80°C are normal.
The carbonator pump switches on automatically and fills the carbonator. The carbonator pump switches off
when the water has reached its highest level in the carbonator container but after no more than 20 minutes.
Long run periods are signs of leaks or too large extraction. It is then only possible to turn the pump back on by
a power network reset (pulling out the mains plug briefly).