Cornelius NORDIC ELITE Series Скачать руководство пользователя страница 9

Installation Guide and Owner’s Manual

© 2018, Cornelius Inc.

- 5 -

Publication Number: 548000033

NOTE: The purge drain fitting is plastic: DO NOT apply heat to purge drain area; DO NOT over-tighten drain 

connection.

All drain lines must be installed per local codes. The purge drain should be a minimum of 3/4 inch O.D. tubing. The 
condenser drain on water cooled units should be 1/2 inch O.D. minimum. The drain line fittings on Cornelius bins are 
3/4 FPT. The bin drain should be a minimum of 3/4 inch O.D. Cold water drains should be insulated to prevent con-
densation from forming.

C

LEARANCE

 R

EQUIREMENTS

Self-contained air cooled ice machines must have a minimum of 6 inches (15cm) of clearance at the rear, top, and 
sides for proper air circulation and adequate space for serviceability.

Self-contained air-cooled ice machines exhaust air out of the top and right side. There are two alternative air exhaust 
options. Option A (top exhaust bias): minimum of 6 inches (15cm) of clearance at the rear and top of the ice machine 
for proper function at maximum operating conditions. Option B (side exhaust bias): minimum of 6 inches (15cm) of 
clearance at the rear and right side of the ice machine with a minimum of 3 inches (7.5cm) of clearance at the top for 
proper function at maximum operating conditions.

Appropriate space should be allowed for proper serviceability of the machine. Excess time to gain access for service-
ability is 

not covered under warranty.

S

TACKING

Cornelius does not endorse stacking ice machines.

D

ISPENSER

 A

PPLICATION

A thermostatic bin control kit should be installed if the ice machine is placed on a dispenser. A bin top may or may not 
be required and should be secured to the dispenser.

E

LECTRICAL

 S

PECIFICATIONS

Refer to the serial plate at the rear of the ice machine to make sure proper voltage and circuit breaker size have been 
supplied. Make sure the machine is on a dedicated circuit. European installations require that the electrical supply 
fixed wiring must be provided with a disconnect means having a separation of at least 3mm in all poles. The ice 
machines are provided 

without

 an electrical cord set and are designed and agency approved to be permanently con-

nected.

NOTE: Units are not approved for GFI outlets.

CAUTION

!

 Electrical connection must be made or a cord installed by a qualified electrician or there is danger of an electrical 
fire.

A

DJUSTMENTS

Level the machine within 1/8 inch in all directions. Check the water in the Water Sump for proper level.

Check the ice bridge for proper thickness. Check the Water Regulating Valve adjustment if water cooled.

Secure the machine on top of the bin or dispenser. Attach the ice machine to the bin with the mounting straps pro-
vided with the bin or dispenser. Insure that the back of the ice machine is flush with the back of the bin. Proper func-
tioning of the Bin Door requires the door, when it is opened, to be in a stable position.

If the ice machine is too far forward on the bin, the opened door may not be stable, resulting in an unexpected closing 
of the bin door. If the ice machine is to be mounted on a bin or dispenser other than a Cornelius, refer to the manufac-
turers instructions for machine mounting. Cornelius will not be responsible for damage or injury that results from unex-
pected closing of the bin door as a result of the ice machine being too far forward on the bin.

Содержание NORDIC ELITE Series

Страница 1: ...R CNM 300 lb THROUGH 1400 lb CUBERS OWNER S MANUAL Release Date April 19 2018 Publication Number 548000033 Revision Date December 18 2018 Revision B Visit the Cornelius web site at http ice cornelius...

Страница 2: ...pair or the failure to utilize suitably qualified and trained per sons to perform service and or repair of the Product 10 improper cleaning 11 failure to follow installation oper ating cleaning or mai...

Страница 3: ...y 7 INSTALLATION GUIDELINES 8 Ambient Operating Temperature 8 Incoming Water Supply 8 Water Filtration Treatment 8 Drains 8 Clearance Requirements 9 Stacking 9 Dispenser Application 9 Electrical Speci...

Страница 4: ...16 CNM Control Board 16 START UP PROCEDURE 17 General Maintenance Procedure 18 CLEANING INSTRUCTION FOR CORNELIUS CNM SERIES ICE MACHINES 19 Chemicals for Descaling and Sanitizing 21 Cleaning Stainle...

Страница 5: ...icates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury or equipment damage SAFETY TIPS Carefully read and follow all safety messages in this manual and sa...

Страница 6: ...or relocating the unit the unit must be sanitized and all sanitizing solution must be drained from the system A freezing ambient environment will cause residual sanitizing solution or water remaining...

Страница 7: ...manual as an aid to the service technician in installation and maintenance of the Nordic Series cube ice machines Do not attempt to perform installation start up or maintenance unless you have read a...

Страница 8: ...20 psi 1 4 bar 0 138MPa Maximum incoming water pressure 80 psi 5 5 bar 0 552MPa NOTE If water pressure exceeds 80 psi 5 5 bar a water pressure regulator must be installed All water supply lines must b...

Страница 9: ...ce machine is placed on a dispenser A bin top may or may not be required and should be secured to the dispenser ELECTRICAL SPECIFICATIONS Refer to the serial plate at the rear of the ice machine to ma...

Страница 10: ...that rises then falls then rises or a line set that falls then rises then falls REMOTE CONDENSER LOCATION Pre charged line sets are available in 25 40 or 75 foot length to connect the ice machine to...

Страница 11: ...Have the roofing contractor seal the holes in the roof per local codes CAUTION The couplings on the sets of pre charged lines are self sealing when installed properly Carefully follow the instruction...

Страница 12: ...c EQUIVALENT RUN CALCULATION EXAMPLES Formula for maximum equivalent run RISE x 1 7 DROP x 6 6 HORIZONTAL RUN EQUIVALENT RUN NOTE NOT TO EXCEED 100 CALCULATED FEET Rise 35 ft x 1 7 40 ft 99 5 equivale...

Страница 13: ...T C Hole for electrical connections 7 8 D Electrical junction box 7 8 Figure 3 CNM 22 W R 0 5 6 Water Remote Cooled A Ice maker potable water in 3 8 FPT B Ice maker water out 3 4 FPT C Hole for electr...

Страница 14: ...rical connections 7 8 D Electrical junction box 7 8 Figure 5 CNM 30 W R 0 5 6 Water Remote Cooled A Ice maker potable water in 3 8 FPT B Ice maker water out 3 4 FPT C Hole for electrical connections 7...

Страница 15: ...rical connections 7 8 D Electrical junction box 7 8 Figure 7 CNM 48 W R 6 Water Remote Cooled A Ice maker potable water in 3 8 FPT B Ice maker water out 3 4 FPT C Hole for electrical connections 7 8 D...

Страница 16: ...Sump At the conclusion of Anti Slush the unit will continue in freeze mode until the Low Water Float is satisfied closes indicating the formation of a full slab of Ice on the Evaporator and will star...

Страница 17: ...n of CNM Series Cuber in this manual Check operation of each component through the cycle as explained in this section Figure 10 Bridge Thickness Adjustment Once the unit has gone through a harvest cyc...

Страница 18: ...in Sump See Figure 11 for proper water level and adjustment procedure 4 Clean the condenser air cooled machines to ensure unobstructed air flow 5 Check for leaks of any kind water refrigerant oil etc...

Страница 19: ...and slime The manufacturer requires a nickel safe sanitizer such as Nu Calgon IMS III or equivalent diluted per manufacturer s instructions CAUTION Do not mix cleaner descaler and sanitizer together N...

Страница 20: ...soft cloth the evaporator water spillway water distributor upper evaporator cover lower evaporator curtain and all splash surfaces Verify that all residue and residual miner als have been removed 16 I...

Страница 21: ...oking like new 1 Clean the stainless steel and aluminum thoroughly once a week Clean frequently to avoid build up of hard stubborn stains Hard water stains left to sit can weaken the metals corrosion...

Страница 22: ...ice is off of the evaporator s If ice is being made initiate harvest by pressing the Power Button for approximately 3 seconds The unit will shut off automatically following the harvest 3 Disconnect th...

Страница 23: ...ness while moving this float down decreases the bridge thickness 4 Why is my new machine occasionally producing extra thick batches of ice When occasional thick batches of ice occur the bridge thickne...

Страница 24: ...ilable on the inside of the left panel of the machine but a basic description is as follows Solid or Blinking Blue A blue light indicates the machine is operating normally It could be making ice waiti...

Страница 25: ......

Страница 26: ...Cornelius Inc www cornelius com...

Отзывы: