Cornelius NORDIC ELITE Series Скачать руководство пользователя страница 6

Installation Guide and Owner’s Manual

Publication Number: 548000033

- 2 -

© 2018, Cornelius Inc.

S

AFETY

 P

RECAUTIONS

This unit has been specifically designed to provide protection against personal injury. To ensure continued protection 
observe the following:

Disconnect power to the unit before servicing, following all lock out/tag out procedures established 
by the user. Verify all the power is off to the unit before any work is performed. Failure to disconnect 
the power could result in serious injury, death or equipment damage.

Always be sure to keep area around the unit clean and free of clutter. Failure to keep this area clean 
may result in injury or equipment damage.

Shipping And Storage

Before shipping, storing, or relocating the unit, the unit must be sanitized and all sanitizing solution 
must be drained from the system. A freezing ambient environment will cause residual sanitizing 
solution or water remaining inside the unit to freeze resulting in damage to internal components.

Unit Location

Machine Usage

WARNING

!

CAUTION

!

CAUTION

!

CAUTION

!

This unit is not designed for use in outdoor locations.

The appliance must be placed in a horizontal position.

The appliance is not suitable for installation in an area where a water jet would be used.

CAUTION

!

This appliance is not intended for use by persons (including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

Содержание NORDIC ELITE Series

Страница 1: ...R CNM 300 lb THROUGH 1400 lb CUBERS OWNER S MANUAL Release Date April 19 2018 Publication Number 548000033 Revision Date December 18 2018 Revision B Visit the Cornelius web site at http ice cornelius...

Страница 2: ...pair or the failure to utilize suitably qualified and trained per sons to perform service and or repair of the Product 10 improper cleaning 11 failure to follow installation oper ating cleaning or mai...

Страница 3: ...y 7 INSTALLATION GUIDELINES 8 Ambient Operating Temperature 8 Incoming Water Supply 8 Water Filtration Treatment 8 Drains 8 Clearance Requirements 9 Stacking 9 Dispenser Application 9 Electrical Speci...

Страница 4: ...16 CNM Control Board 16 START UP PROCEDURE 17 General Maintenance Procedure 18 CLEANING INSTRUCTION FOR CORNELIUS CNM SERIES ICE MACHINES 19 Chemicals for Descaling and Sanitizing 21 Cleaning Stainle...

Страница 5: ...icates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury or equipment damage SAFETY TIPS Carefully read and follow all safety messages in this manual and sa...

Страница 6: ...or relocating the unit the unit must be sanitized and all sanitizing solution must be drained from the system A freezing ambient environment will cause residual sanitizing solution or water remaining...

Страница 7: ...manual as an aid to the service technician in installation and maintenance of the Nordic Series cube ice machines Do not attempt to perform installation start up or maintenance unless you have read a...

Страница 8: ...20 psi 1 4 bar 0 138MPa Maximum incoming water pressure 80 psi 5 5 bar 0 552MPa NOTE If water pressure exceeds 80 psi 5 5 bar a water pressure regulator must be installed All water supply lines must b...

Страница 9: ...ce machine is placed on a dispenser A bin top may or may not be required and should be secured to the dispenser ELECTRICAL SPECIFICATIONS Refer to the serial plate at the rear of the ice machine to ma...

Страница 10: ...that rises then falls then rises or a line set that falls then rises then falls REMOTE CONDENSER LOCATION Pre charged line sets are available in 25 40 or 75 foot length to connect the ice machine to...

Страница 11: ...Have the roofing contractor seal the holes in the roof per local codes CAUTION The couplings on the sets of pre charged lines are self sealing when installed properly Carefully follow the instruction...

Страница 12: ...c EQUIVALENT RUN CALCULATION EXAMPLES Formula for maximum equivalent run RISE x 1 7 DROP x 6 6 HORIZONTAL RUN EQUIVALENT RUN NOTE NOT TO EXCEED 100 CALCULATED FEET Rise 35 ft x 1 7 40 ft 99 5 equivale...

Страница 13: ...T C Hole for electrical connections 7 8 D Electrical junction box 7 8 Figure 3 CNM 22 W R 0 5 6 Water Remote Cooled A Ice maker potable water in 3 8 FPT B Ice maker water out 3 4 FPT C Hole for electr...

Страница 14: ...rical connections 7 8 D Electrical junction box 7 8 Figure 5 CNM 30 W R 0 5 6 Water Remote Cooled A Ice maker potable water in 3 8 FPT B Ice maker water out 3 4 FPT C Hole for electrical connections 7...

Страница 15: ...rical connections 7 8 D Electrical junction box 7 8 Figure 7 CNM 48 W R 6 Water Remote Cooled A Ice maker potable water in 3 8 FPT B Ice maker water out 3 4 FPT C Hole for electrical connections 7 8 D...

Страница 16: ...Sump At the conclusion of Anti Slush the unit will continue in freeze mode until the Low Water Float is satisfied closes indicating the formation of a full slab of Ice on the Evaporator and will star...

Страница 17: ...n of CNM Series Cuber in this manual Check operation of each component through the cycle as explained in this section Figure 10 Bridge Thickness Adjustment Once the unit has gone through a harvest cyc...

Страница 18: ...in Sump See Figure 11 for proper water level and adjustment procedure 4 Clean the condenser air cooled machines to ensure unobstructed air flow 5 Check for leaks of any kind water refrigerant oil etc...

Страница 19: ...and slime The manufacturer requires a nickel safe sanitizer such as Nu Calgon IMS III or equivalent diluted per manufacturer s instructions CAUTION Do not mix cleaner descaler and sanitizer together N...

Страница 20: ...soft cloth the evaporator water spillway water distributor upper evaporator cover lower evaporator curtain and all splash surfaces Verify that all residue and residual miner als have been removed 16 I...

Страница 21: ...oking like new 1 Clean the stainless steel and aluminum thoroughly once a week Clean frequently to avoid build up of hard stubborn stains Hard water stains left to sit can weaken the metals corrosion...

Страница 22: ...ice is off of the evaporator s If ice is being made initiate harvest by pressing the Power Button for approximately 3 seconds The unit will shut off automatically following the harvest 3 Disconnect th...

Страница 23: ...ness while moving this float down decreases the bridge thickness 4 Why is my new machine occasionally producing extra thick batches of ice When occasional thick batches of ice occur the bridge thickne...

Страница 24: ...ilable on the inside of the left panel of the machine but a basic description is as follows Solid or Blinking Blue A blue light indicates the machine is operating normally It could be making ice waiti...

Страница 25: ......

Страница 26: ...Cornelius Inc www cornelius com...

Отзывы: