Installation Guide and Owner’s Manual
© 2018, Cornelius Inc.
- 7 -
Publication Number: 548000033
Have a roofing contractor cut a minimum hole for the refrigerant lines of 2.50 inch. Check local codes, a separate hole
may be required for the electrical power to the condenser.
CAUTION
!
DO NOT KINK OR CRIMP REFRIGERANT TUBING WHEN INSTALLING IT.
Route the refrigerant lines through the roof opening. Follow straight line routing whenever possible. Any excess tubing
MUST remain with the building. Spiral the excess length of pre-charged tubing inside the building. Use a horizontal
spiral to avoid any traps in the lines. Have the roofing contractor seal the holes in the roof per local codes.
CAUTION
!
The couplings on the sets of pre-charged lines are self sealing when installed properly. Carefully follow
the instructions in the Remote Condenser manual.
The following remote ice makers incorporate the Mixing Valve in the condenser. This configuration allows up to a 100
foot calculated remote line set run. Reference the diagram on the next page to calculate the maximum 100 ft. line set
run. Maximum
actual line set run
is limited to 100 ft. Add 1/4 oz. of refrigerant for each actual foot from 75 to 100 ft.
actual line set run.
NOTE: *Verify the ice machine is compatible with the remote condenser. For more information contact your
distributor.
CNM Machine Model Number
Remote Condenser Model Number
CNM0630R/0830R/1030R
RCN1061