7. Remove platic coupler from the old beater drive motor shaft and install on the new motor shaft. MAKE
SURE THE ALLEN-HEAD SET SCREWS ARE SECURELY TIGHTENED AND PROPERLY SEATED ON
THE SHAFT FLAT SURFACE.
CAUTION: The new beater drive motor has a screw in the vent hole on top of the gear box
that must be removed before the motor is put into operation.
8. Remove the screw from the vent hole on top of the beater drive motor gear box. BE CAREFUL NOT TO
LAY THE MOTOR ON IT’S SIDE WHICH WILL CAUSE OIL TO LEAK OUT OF THE GEAR BOX.
9. Very carefully, place the new beater drive motor into position in the Unit with the motor shaft engaged in the
beater drive shaft large plastic coupler.
10. Secure beater drive motor to the Unit frame with bolt, hex nuts, and lockwashers.
11. Connect the beater drive motor electrical wiring to the terminal block.
12. Install the sides and back panels by reversing the removal procedures.
13. Restore the Unit to operation.
14. Refer to “PROGRAMMING FREEZE CYLINDER BEATER MOTORS INTO UNIT ELECTRONICS” in the
SERVICE AND MAINTENANCE section to program the new replacement beater motor into the Unit to
match the Unit electronics.
ADJUSTING CARBONATED WATER TANKS LIQUID LEVEL
The carbonated water tank liquid level (pump cut-in and cutout) was adjusted at the factory and should require
no further adjustment. However, if incorrect setting is suspected, check and make necessary adjustments as
follows:
1. Remove Unit back and side panels as instructed for access to the carbonated water tanks and the
carbonated water volume sample valves (see Figure 2 and 5).
2. To check carbonator tank total fill; allow carbonator water pump motor to operate and fill tank with
carbonated water. After pump cycles off, disconnect electrical power from Unit.
3. Using container graduated in ounces, open applicable carbonated water tank carbonated water sample
valve and completely drain carbonated water tank into the container. Total carbonated water volume
dispensed should be 40 to 58-ounces maximum.
4. If total carbonated water dispensed is below 40-ounces, loosen screw securing level control switches
actuator bracket (see Figure 14) and move actuator bracket up slightly. If more than 58-ounces, maximum
of carbonated water was dispensed, move actuator bracket down, then tighten screw. MAKE
ADJUSTMENTS IN SMALL INCREMENTS.
5. Connect electrical power to Unit and allow carbonated water tank to fill with water and until water pump
cycles off.
6. Repeat steps 2 through 5 preceding as many times as necessary until correct carbonated water volume
adjustment is achieved.