
44
312026000
5. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to advance viscosity number to desired setting. Press
‘‘DEFROST’’ (SELECT) switch to lock in viscosity setting.
6. Press ‘‘ERROR RESET’’ switch two times to exit from MENU SELECTIONS.
‘‘VIS READ’’ (ACTUAL VISCOSITY READOUT) OF PRODUCT IN FREEZE CYLINDERS
‘‘VIS READ’’ (ACTUAL VISCOSITY READOUT) may be brought up on message display to actually read the
viscosity (product consistency) of the product in the freeze cylinders while the Unit is in operation. Bring ‘‘VIS
READ’’ up on message display as follows:
1. Refer to PROGRAMMING MENU SELECTIONS ON MESSAGE DISPLAY and bring up ‘‘VIS READ’’ of
product in freeze cylinders.
2. Press ‘‘DEFROST’’ (SELECT) switch to bring up actual viscosity readout of product in each freeze cylinder.
3. Press ‘‘ERROR RESET’’ switch two times to exit from MENU SELECTIONS.
DISPLAYED EVAPORATOR REFRIGERATION COILS INLETS AND COMMON OUTLET
SENSORS TEMPERATURES.
Evaporator refrigeration coils inlet and common outlet temperature readings in degrees Fahrenheit may be
displayed on message displays as follows:
1. Refer to PROGRAMMING MENU SELECTIONS ON MESSAGE DISPLAY and bring up ‘‘SENSORS’’
(TEMPERATURES READOUT) on message display.
2. Press ‘‘DEFROST’’ (SELECT) switch to bring up evaporator refrigeration coils inlet and common outlet
temperature readings in degrees Fahrenheit.
Left Reading–Refrigeration Coils Inlet No. 1
Middle Reading–Refrigeration Coils Inlet No. 2
Right Reading–Common Outlet
3. Press ‘ERROR RESET’’ switch two times to exit from MENU SELECTIONS.
‘‘VOLTAGE’’ (DISPLAYED VOLTAGE READOUT)
Displayed voltage readout may be displayed on message display as follows:
1. Refer to PROGRAMMING MENU SELECTIONS ON MESSAGE DISPLAY and bring up ‘‘VOLTAGE’’
(DISPLAYED VOLTAGE READOUT) on message display.
2. Press ‘‘DEFROST’’ (SELECT) switch to bring up voltage readout on message display.
3. Press ‘‘ERROR RESET’’ switch two times to exit from MENU SELECTIONS.
PROGRAMMING COMPONENTS ‘‘DIAGNOSE’’ (DIAGNOSTIC MODE) INTO UNIT
‘‘DIAGNOSE’’ (DIAGNOSTIC MODE) may be programmed into the Unit to check certain components for
operation. Program ‘‘DIAGNOSE’’ into Unit and check components for proper operation as follows:
1. Refer to PROGRAMMING MAIN MENU SELECTIONS ONTO MESSAGE DISPLAY and bring up the word
‘‘CLOCK’’ on display.
Содержание FCB 3 H.P. POST-MIX DISPENSER
Страница 23: ...16 312026000 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 69: ......
Страница 70: ...62 312026000 FIGURE 17 WIRING DIAGRAM 3584 Rev C...