![Cornelius Enduro-300 IntelliCarb Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/cornelius/enduro-300-intellicarb/enduro-300-intellicarb_operators-manual_2668173008.webp)
5
620919505
CLEANING INTERIOR SURFACES
CAUTION: When pouring liquid into the hopper, do not exceed the rate of 1/2–gallon
per minute.
Important:
Perform the following at least once a month.
1. Remove agitator assembly (see Figure1).
2. Using a nylon bristle brush or sponge, clean the interior of the hopper, top cover and agitator assembly with
soap solution. Thoroughly rinse the hopper, cover and agitator surfaces with clean potable water.
3. Reassemble agitator assembly. Take special care to ensure that the thumbscrew is tight.
4. Using a mechanical spray bottle filled with sanitizing solution, spray the entire interior and agitator assem-
bly. Allow to air dry.
5. Remove merchandiser and ice chute cover from unit.
6. With a nylon bristle brush or sponge, clean the inside of the ice chute, gasket, and cover with soap solution
and rinse thoroughly to remove all traces of detergent.
7. Reassemble ice chute assembly.
8. Using a mechanical spray bottle filled with sanitizing solution, spray the inside of the ice chute. Allow to air
dry.
9. Reinstall merchandiser.
BEVERAGE SYSTEM
(IF APPLICABLE)
WARNING: Disconnect Power Before Cleaning! Do not use metal scrapers, sharp objects or
abrasives on the ice storage hopper, top cover and the agitator disk, as damage may result.
Do not use solvents or other cleaning agents, as they may attack the plastic material.
Soap solution - Use a mixture of mild detergent and warm (100
°
F) potable water.
Sanitizing solution - Dissolve 2 packets (4 oz) Stera Sheen Green Label into 2 gallons of warm (80–100 deg F)
water to insure 200 ppm of available chlorine.
Cleaning tank - Fill clean, empty tank with a mixture of mild detergent and five (5) gallons of warm
potable water (120
°
F).
CAUTION: When pouring liquid into the hopper, do not exceed the rate of 1/2–gallon
per minute.
COLD PLATE
1. Remove splash panel.
2. Remove or move the plastic cold plate cover to expose the cold plate.
3. Locate and remove any debris from the drain trough. Check that the drain holes are not clogged.
4. Pour small amount of soap solution through cold plate openings in hopper.