![Cornelius Enduro-300 IntelliCarb Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/cornelius/enduro-300-intellicarb/enduro-300-intellicarb_operators-manual_2668173013.webp)
10
620919505
Trouble
Remedy
Probable Cause
BEVERAGES TOO SWEET
(CONT’D)
B.
No CO
2
pressure in
carbonator.
B.
Restore CO
2
pressure in
carbonator.
C.
Faucet brix rerequires
adjusting.
C.
Adjust faucet brix.
BEVERAGES NOT SWEET
ENOUGH
A.
Empty syrup tank.
A.
Replenish syrup supply.
B.
Faucet brix rerequires
adjusting.
B.
Adjust faucet brix.
BEVERAGES NOT COLD
(UNITS WITH BUILT–IN COLD
PLATE)
A.
Unit standing with no ice in
hopper–no ice in cold plate
cabinet.
A.
Replenish ice supply.
CARBONATOR PUMP MOTOR
WILL NOT OPERATE.
A.
Unit power cord unplugged or
circuit breaker open in panel
box.
A.
Plug in Unit power cord or reset
circuit breaker.
B.
Inoperable pump motor.
B.
Replace pump motor as
instructed.
C.
Overheated motor cut off by
thermal overload protector.
C.
Check for proper line voltage.
Check for restricted pump
discharge.
D.
Inoperative liquid level control
module.
D.
Replace liquid level control
module as instructed.
E.
Liquid level sensing device
inside carbonator tank
inoperable.
E.
Replace sensing device as
instructed.
F.
Loose electrical connection
and/or open electrical circuit.
F.
Tighten connection and/or repair
open circuit. Check line voltage.
G.
Carbonator pump binding (new
or replacement pumps only).
G.
Remove carbonator pump from
motor, rotate pump or motor shaft
180 degrees, then recouple pump
to motor.
H.
Carbonator pump damaged.
H.
Replace carbonator pump as
instructed.
CARBONATOR PUMP MOTOR
WILL NOT SHUT OFF.
A.
Liquid level sensing device
inside carbonator tank
inoperable.
A.
Replace sensing device as
instructed.
B.
Loose electrical connection
and/or open electrical circuit.
B.
Tighten connection and/or repair
open circuit.
C.
Inoperable liquid level control
module.
C.
Replace liquid level control
module as instructed.
D.
Leak in carbonated water
system.
D.
Repair carbonated water system.
ERRATIC CYCLING OF
CARBONATOR.
A.
Liquid level sensing device
inside carbonator tank
inoperable.
A.
Replace sensing device as
instructed.
B.
Liquid level control module
inoperable.
B.
Replace liquid level control
module as instructed.