©
2017, Cornelius Inc.
- 7 -
Installation
Warning – The device should be serviced by trained and qualified electrician, pipe technician and
refrigeration technician. All wiring and piping installation must be in accordance with national and local codes.
Arrival inspections and unpacking
Inspection of packaging
The package is subject to immediate inspection after arrival. If the device is found damaged or incomplete,
please retain evidence immediately by taking pictures or in other ways and notify the forwarder of the defects
and submit a compensation order to it.
Unpacking
Remove the packing tape and other packing materials. Open the box and make sure that all parts are
complete.
Main parts
Name
Quantity
Tower and taps
1
Nitrogen infusion Unit
1
Pipes, fittings and accessory kit
1
Coffee keg
2
Installation requirements
Minimum space for nitrogen infusion unit under the counter: 700mm (W) * 820mm (H) * 460mm (D)
Minimum space for gas cylinder under the counter: 200mm (W) * 820mm (H) * 460mm (D)
Ambient temperature: 10
℃
to 30
℃
indoor environment
Power supply parameter: 220V 60Hz or 220V 50Hz (See nameplate)
Danger
Be sure to use a separate and three-pin power socket with reliable grounding wire. The used circuit lines need
to be able to withstand a current of 10A and above and the circuits must be connected to a 10A circuit breaker
which has leakage protection function. All wiring must conform to national and local regulations.
Attention
-
The machine is not suitable for areas where water splash exists as water splash may cause damage to the
device.
-
The device is only suitable for indoor (non-harsh environment) applications.
-
Ambient (room) temperature should not exceed 30
℃
and relative humidity should not exceed 75%. Using
it at temperature higher than 30 °C may cause malfunction of the system.
-
Do not place the device in environment where temperature is below 10
℃
, or the device may not function
properly.
-
Remove any debris on heat exchange vent on the top and in the rear of the machine.
-
To avoid overheating of and damage to the pre-cooling body, the top and external walls of the device must
be at least75mm away from the objects around it.
Содержание Cascata180
Страница 18: ... 2017 Cornelius Inc 17 ...
Страница 19: ... 2017 Cornelius Inc 18 ...
Страница 20: ...Cornelius Tianjin Co Ltd www cornelius com cn ...