ABS 2.0 Service Manual
Publication Number: 621058590SER
- 42 -
© 2019, Cornelius Inc.
E
MPTY
C
UP
T
UBE
S
ENSOR
If the cup grabber arms close completely and do not encounter a cup, a sensor will detect that no cup was gripped by
the grabber arms. This will cause a “Empty Cup Tube” message to be sent. See the sequence of events above for a
full description of this sensor.
CAUTION:
!
Do Not attempt any repair until the ABS 2.0 unit has been shut down and the air/CO
2
has been shut OFF. Serious
injury could occur if the cup grabber activates during repair.
R
EPLACEMENT
of C
UP
G
RABBER
P
ADS
Remove the rubber pads from the picker arms by first cutting the edge of RTV at the base of the pads and then
pulling the pads off the picker arms. Install new pads by sliding them on to the picker arms making sure to align and
seat the circular protrusions inside the pads to the circular cutouts on the arms. Apply a line of RTV to the back
edge of the pads to prevent liquid ingress.