![Cornelius ABS 2.0 Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/cornelius/abs-2-0/abs-2-0_service-manual_2667758054.webp)
ABS 2.0 Service Manual
Publication Number: 621058590SER
- 48 -
© 2019, Cornelius Inc.
DISPENSING VALVE
V
ALVE
D
ESCRIPTION
The dispensing valve is located behind the
splash panel and is made up of 3 blocks of 4 valves/solenoids. The
blocks are mounted to the outlet of the cold-plate. The outlets of the valves are plumbed to the nozzle. The front
view is shown below.
Figure 83.
S
HUT
-
OFF
C
ONTROLS
The shut-offs are used mainly for service to shut-off a brand (Syrup) in the case of a leaky solenoid, etc.
Refer to the valve back block and removed section.
F
LOW
C
ONTROLS
The flow controls are used to set the flow rates for the CW, PW and all the syrups.
The flow rate is increased by turning the adjusting screw clockwise and decreased by turning it counterclockwise.
The flow controls are removable by removing the two retaining screws on each side of the control. After shuttling of
flow and de-pressurizing.
S
OLENOID
V
ALVES
The solenoid valves are 30V DC electrically operated valves and are controlled by the MFV. The valve can be taken
apart for cleaning or component replacement. A good valve read 9.1 ohms
Содержание ABS 2.0
Страница 6: ... IV ...
Страница 64: ...ABS 2 0 Service Manual Publication Number 621058590SER 58 2019 Cornelius Inc ...
Страница 65: ...ABS 2 0 Service Manual 2019 Cornelius Inc 59 Publication Number 621058590SER ...
Страница 66: ...ABS 2 0 Service Manual Publication Number 621058590SER 60 2019 Cornelius Inc ...
Страница 67: ......
Страница 68: ...Cornelius Inc www cornelius com ...