Cornelius 221001320 Скачать руководство пользователя страница 2

Legal notice

Operator manual (Original)

Document no. TD1002000

Undercounter cooler
Energize 2 HC: Unit ID no. 221002210
Energize 3 HC: Unit ID no. 221001320
Energize 3v HC: Unit ID no. 221001330
Energize 4 HC: Unit ID no. 221001420
Energize 5 HC single: Unit ID no. 221002571
Energize 5 HC dual: Unit ID no. 221002570

Energize 2-5 HC

Version
Date of issue: 01/10/2019
Revision status: Index 2

www.cornelius-emea.com

Cornelius Deutschland GmbH
Carl-Leverkus-Str. 15 
40764 Langenfeld 
Germany

Tel.: +49 (0) 21 73 / 79 3 – 0
Fax: +49 (0) 21 73 / 77 4 – 38
E-Mail: [email protected]

Protection notices (in accordance with DIN ISO 16016:2017-08)

The reproduction, distribution and utilisation of this document as well as the communication of
its contents is prohibited, unless expressly permitted. Violations shall result in an obligation to
pay damages. All rights reserved with regard to filing for/registering patents, utility models or
design patents.

Obligation to preserve records

Please keep this Operator Manual and the Declaration of Conformity in a safe place and trans-
fer them to the subsequent owner/operator if the unit is transferred or sold.
If you lose the Operator Manual or the Declaration of Conformity, you can download them from
the website below or request a printed copy from the address below.

Содержание 221001320

Страница 1: ...Operator manual Undercounter cooler Energize 2 5 HC...

Страница 2: ...elius com Protection notices in accordance with DIN ISO 16016 2017 08 The reproduction distribution and utilisation of this document as well as the communication of its contents is prohibited unless e...

Страница 3: ...semblies and components 13 3 1 1 Undercounter cooler Energize 2 HC 13 3 1 2 Undercounter cooler Energize 3 HC 14 3 1 3 Undercounter cooler Energize 3v HC 15 3 1 4 Undercounter cooler Energize 4 HC 16...

Страница 4: ...Energize 5 HC dual 26 3 3 8 CO2 working pressures 26 3 3 9 Control and indicator panel 27 4 Operation 28 4 1 Commissioning 28 4 2 Changing product containers 30 4 3 Shutdown 31 5 Maintenance 32 5 1 Ma...

Страница 5: ...allation is to be carried out by an expert in compliance with all of the specifications given in the installation and service manual see the document Undercounter cooler installation and service manua...

Страница 6: ...ning and maintenance work must not be carried out by children unattended Use by those under the influence of medication alcohol drugs or other substances which impair their physical sensory or mental...

Страница 7: ...and be ex pressly charged with its use This document is to be available to staff at all times If this unit is openly accessible and set up so that untrained staff can use it the operator is to provid...

Страница 8: ...a high risk2 which results in serious injuries or death if not avoided WARNING marks a danger with a medium risk2 which may result in serious injury or death if not avoided CAUTION marks a danger with...

Страница 9: ...anties If work is undertaken on the unit which is not described in this document Cornelius Deutsch land GmbH shall not assume any liability for any resulting hazards and damages The same applies to de...

Страница 10: ...e unit after it has been in continuous use over an ex tended period of time will result in a risk of burns Take appropriate safeguard measures such as by wearing heat resis tant protective gloves DANG...

Страница 11: ...air and consequently accu mulates at the bottom and may enter lower lying areas e g sewage sys tems At high concentrations this may lead to a lack of oxygen resulting in a risk of suffocation Lower co...

Страница 12: ...e any claim 1 Inspect the cardboard box and make a note of any damage however minimal this may seem If the cardboard box is damaged please make a note of the following on the copy of your freight invo...

Страница 13: ...le ambient conditions If possible store the unit in its original packaging Unpacked units must be covered with a dustproof cover No condensate must form under the cover ATTENTION Risk of electrostatic...

Страница 14: ...water or cleaning agent residue remaining inside the unit This will lead to damage to internal components Before shipment storage or relocation of the unit the unit is to be cleaned and the cleaning...

Страница 15: ...er cooler Energize 2 5 HC 13 3 Description 3 1 Assemblies and components 3 1 1 Undercounter cooler Energize 2 HC The unit comprises the following assemblies Fig 1 1 3 2 6 5 4 1 Cover 2 Cooling unit wi...

Страница 16: ...ator manual Undercounter cooler Energize 2 5 HC 14 3 1 2 Undercounter cooler Energize 3 HC The unit comprises the following assemblies Fig 2 1 2 6 5 4 3 1 Tube connections 2 Cover 3 Control and indica...

Страница 17: ...2 Operator manual Undercounter cooler Energize 2 5 HC 15 3 1 3 Undercounter cooler Energize 3v HC The unit comprises the following assemblies Fig 3 1 2 4 5 3 1 Control and indicator panel 2 Cover 3 C...

Страница 18: ...ator manual Undercounter cooler Energize 2 5 HC 16 3 1 4 Undercounter cooler Energize 4 HC The unit comprises the following assemblies Fig 4 1 2 3 4 5 6 1 Tube connections 2 Cover 3 Control and indica...

Страница 19: ...2 Operator manual Undercounter cooler Energize 2 5 HC 17 3 1 5 Undercounter cooler Energize 5 HC single The unit comprises the following assemblies Fig 5 1 2 3 4 5 1 Tube connections 2 Cover 3 Contro...

Страница 20: ...x 2 Operator manual Undercounter cooler Energize 2 5 HC 18 3 1 6 Undercounter cooler Energize 5 HC dual The unit comprises the following assemblies Fig 6 1 2 3 4 5 1 Tube connections 2 Cover 3 Control...

Страница 21: ...illed to the right temperature in the housing Drinking water is also carbonated This means that still water soda and chilled syrup are available at the re frigerator outlets for postmix beverages When...

Страница 22: ...ter cooler Energize 2 HC Description Parameter Value Unit Dimensions Height 635 25 mm in Width 620 24 4 mm in Depth 410 16 1 mm in Dispensing capacity At a dispensing rate of 2 drinks of 0 3 li tres a...

Страница 23: ...3 5 mm in Depth 470 18 5 mm in Dispensing capacity At a dispensing rate of 2 drinks of 0 3 li tres a minute1 360 at 2 min Unit Ice build up size Weight 18 kg Ice build up capacity 1440 kcal h Power su...

Страница 24: ...13 4 mm in Depth 590 23 2 mm in Dispensing capacity At a dispensing rate of 2 drinks of 0 3 li tres a minute1 360 at 2 min Unit Ice build up size Weight 18 kg Ice build up capacity 1440 kcal h Power s...

Страница 25: ...4 mm in Depth 515 20 3 mm in Dispensing capacity At a dispensing rate of 2 drinks of 0 3 li tres a minute1 700 at 2 min Unit Ice build up size Weight 30 kg Ice build up capacity 2400 kcal h Power supp...

Страница 26: ...tion and service manual document no TD1002100 Description Parameter Value Unit Dimensions Height 810 31 9 mm in Width 1080 42 5 mm in Depth 690 27 2 mm in Dispensing capacity At a dispensing rate of 4...

Страница 27: ...angerous voltage warning sign Fig 8 2 Refrigerant warning sign Fig 8 3 Python connection warning sign Fig 8 4 Carbonator type plate Fig 8 5 Unit type plate Fig 8 4 5 3 2 1 Fig 9 1 Dangerous voltage wa...

Страница 28: ...consecutive metre Fig 11 1 Dangerous voltage warning sign Fig 11 2 Unit type plate Fig 11 3 Python connection warning sign Fig 11 4 Refrigerant warning sign Fig 11 5 Carbonator type plate Fig 11 1 2 3...

Страница 29: ...range CO2 alarm Fig 13 6 LED green power mains Fig 13 1 2 3 4 5 6 LED Status Description Comment Alarm red Off OK No existing error On Not OK see chapter 6 1 Flashing 1 Hz Not OK see chapter 6 1 Flash...

Страница 30: ...injury or equipment damage Please always strictly observe all safety measures and information in structions see chapter 1 The unit has been designed for continuous operation Apart from the daily chec...

Страница 31: ...max imum If necessary fill up the water bath with tap water 2 Check that the CO2 bottle valve is open see documenta tion on the CO2 system If necessary open the valve on the CO2 bottle 3 Check the pre...

Страница 32: ...at needs changing 2 Exchange the empty product container for a full one and remove the protective cap from its connection NOTICE Do not mix up standard and light products as they are conveyed with dif...

Страница 33: ...e carried out by an expert see chapter 1 3 3 as the unit has to be cleaned and drained 1 Close the CO2 bottle valve see documentation on the CO2 system 2 Close the CO2 shut off valves see documentatio...

Страница 34: ...ons see chapter 1 5 1 Maintenance table NOTICE The following table provides information on recommended maintenance in tervals to be adapted to the relevant installation situation Interval Components A...

Страница 35: ...CO2 system If necessary open the CO2 shut off valves 6 Check that the water supply valve is open see documentation on the water supply valve If necessary open the water supply valve 7 Check the press...

Страница 36: ...Cleaning the unit 1 Use a vacuum cleaner to clean the supply and exhaust air grilles of dirt 2 Clean the unit with a clean damp cloth and if necessary an approved cleaning agent 3 Dry the unit with a...

Страница 37: ...r not running Switch on the compressor see chapter 4 1 Please contact your service part ner Beverage is too warm and the com pressor is running Excessive beverage dispensing Do not exceed the maximum...

Страница 38: ...t off valve or pressure reduc ing valve for the fresh water supply is closed Open the shut off valve and pres sure reducing valve for the fresh water supply see documentation on the drinking water sys...

Страница 39: ...the un dercounter cooler see chapter 4 3 Alarm red flashes approx 1x per sec ond Time out due to insufficient water pressure fluctuations carbonator pump is blocked Check the water pressure see chapte...

Страница 40: ...plicable documents Cornelius Deutschland GmbH Document no TD1002000 Version 01 10 2019 Index 2 Operator manual Undercounter cooler Energize 2 5 HC 38 7 Applicable documents 7 1 Declaration of conformi...

Страница 41: ...RI WKH SODFH RI RSHUDWLRQ 1DPH RI WKH SODFH RI RSHUDWLRQ 6WUHHW DGGUHVV KRXVH QR 3RVWFRGH WRZQ 1DPH RI WKH RSHUDWRU 2SHUDWRU FRS 7KH RSHUDWRU KDV EHHQ LQVWUXFWHG LQ WKH XVH RI WKH XQLW DWH 6WDPS DQG...

Страница 42: ...nual Undercounter cooler Energize 2 5 HC 40 QVWDOOHU FRS 7KH RSHUDWRU KDV EHHQ LQVWUXFWHG LQ WKH XVH RI WKH XQLW DWH 6WDPS DQG VLJQDWXUH 2SHUDWRU 6WDPS DQG VLJQDWXUH QVWDOOHU RI WKH XQLW 7KH XQLW KDV...

Страница 43: ...FWHG RQ WKH IROORZLQJ WRSLFV HQHUDO VHTXHQFH RI RSHUDWLRQV 5HIHUHQFH WR H LVWLQJ GRFXPHQWDWLRQ OHDQLQJ WKH XQLW DVW QDPH ILUVW QDPH 6LJQDWXUH DVW QDPH ILUVW QDPH 6LJQDWXUH DVW QDPH ILUVW QDPH 6LJQDWXU...

Страница 44: ...Deutschland GmbH Document no TD1002000 Version 01 10 2019 Index 2 Operator manual Undercounter cooler Energize 2 5 HC 42 5 Date Component alkaline acidic Chemical agent Cleaning agent Carried out by...

Страница 45: ...www cornelius emea com Cornelius Deutschland GmbH Carl Leverkus Str 15 40764 Langenfeld Germany Tel 49 0 21 73 79 3 0 Fax 49 0 21 73 77 4 38 E Mail info cornelius com...

Отзывы: