Technical Support Manual – 03/2017 Rel. 0
Page 10
4
Press on icon.
5
Example
Example
Lower the wheel guard: the
machine will run a launch and
display shaft RPM. The machine
will spin continuously and the
pick-up signals at the three
attenuation processes
(Attenuation 1, Attenuation 2,
Attenuation 4) will be displayed in
sequence. Each attenuation value
reading must be between
70 ÷
120
(See table T8.2).
This sequence repeats until the
wheel stops spinning when the
wheel guard is raised.
If the value of both or one of the
two pick-ups is 0, check the
connection and change the pick-
up, or both, if necessary.
Содержание TOUCH MEC 1000 SONAR
Страница 1: ...WHEEL BALANCERS TOUCH MEC 1000 SONAR TECHNICAL SUPPORT MANUAL UK...
Страница 2: ......
Страница 5: ...Technical Support Manual 03 2017 Rel 0 Page 3 4 At the end of the test the machine is in NORMAL mode 5...
Страница 53: ......