background image

 

Technical Support Manual – 03/2017   Rel. 0                      

Page 39 

 

Press on icon.  

 

 

 

Enter the detected value by 
pressing on icons: 

 

 

 

Lower the wheel guard: the machine will run a launch. 

10 

 

By hand, turn

  the wheel in 

the direction marked by the arrow 
until you see 50 g on the left 
display. 

Содержание TOUCH MEC 1000 SONAR

Страница 1: ...WHEEL BALANCERS TOUCH MEC 1000 SONAR TECHNICAL SUPPORT MANUAL UK...

Страница 2: ......

Страница 3: ...libration 26 3 3 3 SONAR DEVICE operation test 28 3 4 Enable or disable electromagnetic stopping brake 30 3 5 Enable or disable the lighting led 31 3 6 Enable or disable the LASER 33 3 7 MICRO WHEEL G...

Страница 4: ...ine settings and TESTS to help detect any anomalies To access the SERVICE mode proceed as described below Ph 1 Switch the machine ON by pressing the main switch on the back of the wheel balancer then...

Страница 5: ...Technical Support Manual 03 2017 Rel 0 Page 3 4 At the end of the test the machine is in NORMAL mode 5...

Страница 6: ...Support Manual 03 2017 Rel 0 Page 4 6 Press on icon to exit the SERVICE mode and enter in NORMAL mode Picture F1 1 SERVICE menu The programs can be selected in SERVICE mode BY PRESSING ON THE MONITOR...

Страница 7: ...1 CONTROL ICONS key Icon Meaning Launch number counter selection icon Test program menu selection icon Configurations menu activation icon Electromagnetic brake activation icon Illuminator activation...

Страница 8: ...controls the parameters that affect the signal Shaft imbalance test enabling icon Bearing smoothness test enabling icon Reserved for Cormach Technical Assistance Service Encoder disc reading test sele...

Страница 9: ...is used to run the shaft rotation speed test This test allows you to control the number of shaft RPMs during the launch A number indicating the speed of the shaft will be viewed on the right display...

Страница 10: ...eater if motor and pulley are the same If the speed of rotation is much lower than stated ensure that the main supply voltage does not drop excessively during rotation If the main supply voltage is co...

Страница 11: ...the external side of the wheel If the wheel size is different from the measurements provided above the detected pick up signals will differ from those stated in table T8 2 The pick up signals depend...

Страница 12: ...e pick up signals at the three attenuation processes Attenuation 1 Attenuation 2 Attenuation 4 will be displayed in sequence Each attenuation value reading must be between 70 120 See table T8 2 This s...

Страница 13: ...is possible to run this check through the VFC TEST described below If both pick up signals differ significantly from the values provided in table T8 2 and differ from each other check whether The pic...

Страница 14: ...the voltage frequency converter test or VFC on the CPU LCD board The converter voltage frequency test shows two numbers on the displays that represent the electronic control board conversion values T...

Страница 15: ...ups is 0 check the connection and change the pick up or both if necessary 4 Example Press on icon to exit the VOLTAGE FREQUENCY CONVERTER TEST program Il Value A refers to pick up A VFC while value B...

Страница 16: ...4 Repeat step 1 for the other pick up 5 Make sure that the springs and hex keys are perpendicular to the pick up support unit If necessary loosen the screw turn the spring or switch it around the oth...

Страница 17: ...Support Manual 03 2017 Rel 0 Page 15 2 4 ENCODER disc test This menu option is used to run the ENCODER disc test To access the ENCODER TEST program proceed as described below Ph 1 Press on icon 2 Pres...

Страница 18: ...ise When the reset notch on the encoder disc is in position H12 the displayed value must be 000 or it must be reset to 000 if the value is different If the count is incorrect clean the encoder disc ch...

Страница 19: ...devices The configuration must be carried out from the CONFIGURATION MENU on the parameters that are available in SERVICE mode The CONFIGURATION MENU also makes it possible to run a number of operatio...

Страница 20: ...tion icon Inches mm unit of measure wheel dimensions selection icon Iron Zinc balancing weight material selection icon Sensor calibration program activation icon Distance Diameter sensor activation ic...

Страница 21: ...ce diameter sensor This menu option is used to enable or disable the distance diameter sensor This is a dual function To enable disable the DISTANCE DIAMETER SENSOR proceed as follows Ph 1 Press on ic...

Страница 22: ...Support Manual 03 2017 Rel 0 Page 20 3 Accordingly the DISTANCE DIAMETER SENSOR is DISABLED Proceed as described below to RE ENABLE THE DISTANCE DIAMETER SENSOR 4 Press on icon to exit the CONFIGURAT...

Страница 23: ...ble Disable width sensor This menu option is used to enable or disable the width sensor This is a dual function To enable disable the WIDTH SENSOR proceed as follows Ph 1 Press on icon 2 Enter the pas...

Страница 24: ...Technical Support Manual 03 2017 Rel 0 Page 22 3 Accordingly the WIDTH SENSOR is DISABLED Proceed as described below to RE ENABLE THE WIDTH SENSOR 4 Press on icon to exit the CONFIGURATIONS MENU...

Страница 25: ...7 Rel 0 Page 23 3 3 Sensors calibration This menu option is used to enable the sensor calibration program To enable disable the WIDTH SENSOR proceed as follows Ph 1 Press on icon 2 Press on icon to ex...

Страница 26: ...and backwards to test whether the magnetic band takes correct readings The values displayed on the left screen are expressed in millimeters and must match the graduated scale The distance is always m...

Страница 27: ...Technical Support Manual 03 2017 Rel 0 Page 25 Example 3 Example Press on icon to exit the DISTANCE SENSOR OPERATION TEST MENU...

Страница 28: ...TER SENSOR proceed as follows Ph 1 Press on icon 2 Example Position the diameter sensor as shown on the screen The left screen will report the output voltage The voltage must be between 0 99 and 1 13...

Страница 29: ...Technical Support Manual 03 2017 Rel 0 Page 27 3 Example Press on icon to exit the DIAMETER SENSOR CALIBRATION MENU...

Страница 30: ...28 3 3 3 SONAR DEVICE operation test The SONAR DEVICE does not require any calibrating or adjusting It is only possible to check whether the reading is correct To test SONAR DEVICE operation proceed a...

Страница 31: ...Technical Support Manual 03 2017 Rel 0 Page 29 3 Example Verify the presence of voltage and ensure that the value in Volts is not zero 4 Example Press on icon to exit the SONAR DEVICE TEST MENU...

Страница 32: ...g brake This menu option is used to enable or disable the electromagnetic stopping brake This is a dual function To activate and or deactivate the ELECTROMAGNETIC STOPPING BRAKE proceed as described b...

Страница 33: ...e Locking the wheel in the imbalance position at the end of rotation Locking the wheel in the imbalance position pressing the icon with the wheel guard raised Locking the wheel in the imbalance positi...

Страница 34: ...l Support Manual 03 2017 Rel 0 Page 32 2 Enter the password 14061 by pressing these icons in rapid sequence 3 Accordingly the LIGHTING LED IS DISABLED Proceed as described above to RE ENABLE THE LIGHT...

Страница 35: ...is menu option allows you to enable or disable the laser to the application of weights with the program and ALS1 ALS2 This is a dual function To activate deactivate the LASER proceed as follows Ph 1 P...

Страница 36: ...DEACTIVATED Proceed as described above to REACTIVATE the LASER 3 7 MICRO WHEEL GUARD operation test This option allows to control the correct operating of the MICRO SWITCH controlling the WHEEL GUARD...

Страница 37: ...hnical Support Manual 03 2017 Rel 0 Page 35 2 Lower the WHEEL GUARD 3 If the MICRO works properly the machine will display the image as byside 4 Press on icon to exit the MICRO WHEEL GUARD OPERATION T...

Страница 38: ...tion for MOTO Wheel Type Mandatory Final user and or Technical Service When the machine doesn t show accurate results for balancing Recommended Final user and or Technical Service When there are wide...

Страница 39: ...the shaft Lower the wheel guard the machine will run a launch 4 Fit the wheel on the shaft Manually enter the wheel dimensions If the dimensions of the wheel were introduced before entering the calibr...

Страница 40: ...ensor and place it on the wheel as shown here Read the distance value on the graduated scale The distance value is always expressed in millimeters 6 Press on icon Enter the detected value by pressing...

Страница 41: ...Rel 0 Page 39 8 Press on icon Enter the detected value by pressing on icons 9 Lower the wheel guard the machine will run a launch 10 By hand turn the wheel in the direction marked by the arrow until...

Страница 42: ...e machine will run a launch 12 Take off the 50 g weight applied to the inner side identified by the red X in the figure By hand turn the wheel in the direction marked by the arrow until you see 50 g o...

Страница 43: ...on imbalance position see chapter SWI Stop the wheel on imbalance Do not lift the wheel guard and do not press on icon during this procedure 15 Calibration is finished the machine automatically exits...

Страница 44: ...calibration for MOTO a specific adaptor for motorcycle wheels is used and this slightly the shaft balancing If the calibration for MOTO wheel type has not been done and the user try to spin the wheel...

Страница 45: ...ower the wheel guard the machine will run a launch 5 At the end of the launch the machine will display the message shown here Apply the calibration weight to the inner side as shown The calibration we...

Страница 46: ...sition of the weights 8 Lower the wheel guard the machine will run a launch 9 At the end of the launch the machine will display the message shown here Apply the calibration weight to the outer side as...

Страница 47: ...pe and the ALU1 Program Type will remain set and the wheel dimensions will be those which were automatically set by the machine for this kind of calibration If you have anomalies during the calibratio...

Страница 48: ...e the pick up 023 ERROR Pick up B channel excessively high Excessive imbalance or anomaly Turn the machine off and then on again If the error continues check whether pick up is broken Change the pick...

Страница 49: ...Weights program the selected point is too far from the external imbalance position The point must be included within 120 from the external imbalance position 052 WARNING Hidden Weights program the ex...

Страница 50: ...ervice programs to simplify sensor adjustment The acoustic signal is also heard for about two seconds at machine start up allowing the operator to check the operation of the alarm buzzer 7 SPECIAL VIS...

Страница 51: ...rence values for parameters Parameters Value Unit of measure Speed of rotation 135 145 RPM Pick up Signal A 70 120 CPU LCD internal unit Pick up Signal B 70 120 CPU LCD internal unit Voltage frequency...

Страница 52: ...l Support Manual 03 2017 Rel 0 Page 50 9 ELECTRICAL DIAGRAM It is possible to order the following codes 1 Code 21201041 CPU LCD T board 2 Code 21201019 PWRB power supply board 3 Code 21201001 GPB Vide...

Страница 53: ......

Страница 54: ...CORMACH S r l via A Pignedoli 2 42015 CORREGGIO RE ITALY Tel 39 0522 631274 Fax 39 0522 631284 e mail cormach cormachsrl com www cormachsrl com...

Отзывы: