address will be displayed. The SUBNET will display a default class C-
SUBNET there is no read back of the changed SUBNET displayed.
(k) Repeat this process for all the CORE TEC equipment requiring change.
Connecting to the Unit
There are currently three ways to connect to the VCX-7401.
1. Telnet
Password: admin (default)
To change the default password perform the following:
Type:
PASSWORD
<followed by your password (up to 11 characters)>
Where <your password> equals the new password.
For configuration using an Ethernet connection, activate the Telnet function by
the following:
•
Initiating from the Command Prompt - Telnet nnn.nnn.nnn.nnn
•
Use the MS Windows – START – RUN Telnet nnn.nnn.nnn.nnn
(where nnn.nnn.nnn.nnn is the IP address of the unit being configured)
Employ the command set as described below.
Note that the initial IP addresses (factory default) are:
Encoder 192.168.0.253
Decoder 192.168.0.254
Sub net Mask 255.255.255.0
2. Terminal Program
NOTE
: The following procedure is valid for standalone units only and is not
applicable to rack mount units.
The Terminal Program, such as HyperTerminal, configuration procedure uses the
serial connection on the front of the unit.
9
Содержание VCX-7401
Страница 2: ...2 ...
Страница 7: ...VCXNETCONFIG Window 7 ...
Страница 13: ...Main Tab 13 ...
Страница 14: ...Network Tab 14 ...
Страница 15: ...Subchannel Tab 15 ...
Страница 16: ...OSD Tab 16 ...
Страница 17: ...Video Tab 17 ...
Страница 18: ...MPEG4 Tab 18 ...
Страница 19: ...H264 Tab 19 ...
Страница 20: ...Decoder Tab 20 ...
Страница 35: ...Models BASE MODELS VCX 7401 H 264 encode and decode MPEG 4 encode 35 ...
Страница 37: ...Standard Ethernet Pin Out Straight Through Ethernet Pin Out Cross Over Ethernet Pin Out 37 ...
Страница 38: ...38 ...