8
9
SPECiFiCATiON
Sampling Method
Detection Method
Power Supply
Power Consumption
Dimensions
Weight
Operation Environment
Temperature
Relative Humidity
Measurement Range
Lower detection limit
Upper display limit
Precision (at 100 Bq/m³)
7 days
Long term
Accuracy
Passive radon diffusion chamber
Alpha spectrometry
3 LR03 (AAA alkaline battery)
3 years battery life-time
< 250μW
120mm × 69mm × 22.5mm
130 grams (incl. batteries)
0 °C to +40 °C
< 95%
0 Bq/m³
9999 Bq/m³
< 20%
< 10% after 1 month
5% ± 5 Bq/m³
ENGL
iSH
RESPONSiBiLiTY
The monitor and the batteries must not be disposed of as
ordinary household waste. The materials used in Canary can
be recycled. It is the user’s environmental responsibility to
ensure that electronic equipment and batteries are disposed
of in accordance with national regulations. Users should con-
tact the seller or their local authority for information about
environmentally friendly waste disposal.
Canary has a 2-year warranty against system failure. In the
event of incorrect use or operation of the monitor, Corentium
AS cannot be held responsible for any losses resulting from
failure or from the loss of measurement data.