background image

 

©CORE Lighting Limited 2012

 

 

9

 

 
In the menu, the “Unlink” function follows from MODE SLV. Pressing enter takes you to a menu 
showing WDMX ULNK. Press enter at this stage and the unlinking happens (note: it takes 5 seconds 
or so). After pressing enter, the unit returns to the MODE SLV menu. If you don't want to unlink, 
then press MENU UP or MENU DOWN and it will take the unit to the MODE menu without unlinking. 
 
When the unit is unlinked, adding it to a Wireless Solutions transmitter box is just a matter of 
pressing the button on the transmitter box for a brief period (less than 2 seconds). The lamps will 
pick up after about 5 seconds and the SLAVE will show a decimal point statically illuminated in the 
display (lower right corner) and also a LINK LED on the transmitter.  
 
See Section 4.2.2 for instructions on linking to a CORE Master unit. 
 

4.3.

 

Brightness Control “BRI%” and LED “NORM” to “LONG LIFE” 

 

The overall brightness level setting (NORMAL, LOW O/P or LONG LIFE) sets the overall dimmer for 
the unit for all SELF operating, SLAVE and MASTER modes (i.e. self or external control). BRI% then 
allows further control once this is set. 
 
NORMAL sets the overall brightness of the unit to 100%.  
LOW O/P sets overall brightness to 70%  
LONG LIFE is 40%.  
NORMAL operating mode should give over 10-12 hours life on a normal colour cycle. This can 
provide extra brightness for larger illuminations such as architectural building lighting where 
additional light throw is required. LOW O/P is recommended for normal indoor use where lifespan 
will be around 30% longer. LONG LIFE can be regarded as a battery preservation mode to gain over 
100% extra lifetime from a charge.

 

 
BRI% adjusts the brightness as a multiplier of the colour options in “MODE SELF” or “MODE MSTR” 
and is selected as a percentage 0 to 100. It is a useful tool for conserving battery life also. 

 

4.4.

 

“BAT” Battery status Mode 

 
Two options are available: one showing temperature of the battery compartment used as a failsafe 
mechanism to prevent damage through over-charging. The second shows battery voltage. 
 
Note  the symbol “^” shows battery charging is active. “BATT FULL” shows when this is complete. 
 

4.5.

 

TOOLS 

4.5.1.

 

SHOW S/N Serial Number 

 
This is the serial number of the unit (eg “CORE 0216”) and provides the WiFi SSID address based on 
the unique serial number (its WiFi unique identity). The number is set at the factory and is unique to 
each unit. 
 

Содержание Point 30

Страница 1: ...USER MANUAL CORE Lighting Ltd LiPo Battery Wireless Flood Light...

Страница 2: ...CORE Lighting Limited 2012 2 Change History Ver Released Comments 0_3 24 April 2012 3_1 9 May 2012...

Страница 3: ...PSU 4 3 3 Battery Charging Discharging 5 CHARGING 5 DISCHARGING LED Modes 6 LIFESPAN 6 3 4 Battery Temperature 6 4 USER INTERFACE MENU OPTIONS 7 4 1 On Off 7 4 2 MODE 7 4 2 1 MODE SELF 7 SELF COLOUR O...

Страница 4: ...oHS Statement 16 ANNEX 1 Menu Structure 17 Please read this entire manual before using the equipment Please keep the manual in a safe place so you can refer to it in the future Safety Connection insta...

Страница 5: ...mains powered units More than 4 2Bn colour shades including hues of white by using 4 colour channels Ability to replicate warm cool colour temperatures of white light Standard 12 beam angle Simple op...

Страница 6: ...nment 1 4 WIRELESS INTERFACE Each light responds to wireless W DMX commands as a slave Built in W DMX antenna connection of slave units to a lighting desk or a POINT20 30 unit with Master capability U...

Страница 7: ...of diffusers the following beam angles are available by special request 20 40 80 Elliptical versions are also available eg 30 x 5 2 3 LED COLOUR PERFORMANCE LIFESPAN Quality of colour is seen as a cri...

Страница 8: ...upply Unit PSU The unit may be operated by mains power continuously through the Powercon connector The power input range is 100 240VAC at 50 60Hz so may be used worldwide The unit will enter charging...

Страница 9: ...arging LED will turn green If the display LED and head show red this means the battery is disconnected or over temperature Allow to cool down and retry If the problem persists contact CORE Lighting Vo...

Страница 10: ...white light When the battery drops to a particular voltage the low battery red LED is activated permanently on the lower right of the membrane keypad as a warning the battery needs recharging When th...

Страница 11: ...the on board keypad and display or upgradeable to WiFi MODE MSTR This is an upgrade option As a Master unit the light can control slave lights over Wireless DMX or wired DMX MODE SLV Slave unit contr...

Страница 12: ...l need to be connected to the MASTER unit This can be achieved by selecting the ADD UNIT in the MASTER DMX menu Prior to this the SLAVE unit needs to have its wireless disconnected from any other tran...

Страница 13: ...further control once this is set NORMAL sets the overall brightness of the unit to 100 LOW O P sets overall brightness to 70 LONG LIFE is 40 NORMAL operating mode should give over 10 12 hours life on...

Страница 14: ...e SET PIN menu option Section 4 5 6 4 5 5 SET DISP The keyboard display is extinguished after a fixed period of keypad inactivity in order to eliminate glare This function sets the time delay from las...

Страница 15: ...DR DMX Address This is the address channel for Wireless DMX Channels 1 to 506 may be selected although from the selected channel the subsequent 5 channels are then allocated as below Each 5 steps repr...

Страница 16: ...lex functions to be achieved not possible on the keypad such as colour picking static colours using a colour chart Diagnostic information is also available from the unit If the W DMX Transmit upgrade...

Страница 17: ...uthorised dealer from which you purchased this product If your dealer is not equipped to perform the repair of your CORE Lighting product it can be returned directly to CORE Lighting with carriage bei...

Страница 18: ...at this product conforms to the specifications listed in this manual following the provisions of the European R TTE directive 1999 5 EC Restrictions on Hazardous Substances RoHS 2002 95 CE Electromagn...

Страница 19: ...nst harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause...

Страница 20: ...er to optimise the recovery and recycling of the materials they contain and reduce the impact on human health and the environment The consumer must contact their local authority or retailer for inform...

Страница 21: ...CORE Lighting Limited 2012 17 ANNEX 1 Menu Structure See attached sheet...

Отзывы: