6.1 User interface
1 ON
2 OFF
SET
OUT
IN
MIN
CLOCK
TIMER
ELEC.
HEATING
L2
L1
L3
L4
L7
L5
L6
L8
L0
L9
L10
L11
7
5
6
2
3
4
Buttons
1.
Digital Display
2.
Key [UP]
3.
Key [DOWN]
4.
Key [ELEC.HEATING]
5.
Key [ON/OFF]
6.
Key [TIMER]
7.
Key [CLOCK]
The LCD display allows viewing of following parameters and related
icons:
LCD icons
L0
Clock display.
L1
Key lock
L2
Setting parameter adjustment
L3
IN: Lower water temperature (sensed by T2 probe)
L4
Defrost enabled
L5
Fan ventilation enabled
L6
Heat Pump Heating
L7
Hot water: Set Temperature reached, DHW available (HP in
standby mode)
L8
Electric heater enabled
L9
OUT: Upper water temp. (sensed by T3 probe)
L10
Timer ON
L11
Timer OFF
[ON/OFF] KEY
In start-up when the [ON/OFF] key is pressed once, whole
icons are displayed on the controller screen for 3 seconds.
And the unit enters into the standby mode.
In stand by m,ode, press the [ON/OFF] key to put the unit
in RUN MODE, the unit will run on the setted mode. On the
screen are displayed: the running mode, the lower (IN) and
upper (OUT) water temperatures, the timer situation and
the clock time.
Press the [ON/OFF] key again to bring the unit back into
stand-by mode.
Press the [ON/OFF] key and the [ELEC. HEATING] key at
the same time to access the parameters setting.
[UP] AND [DOWN] KEYS
Press these keys to:
• scroll the parameters list (going upward [UP] or
downward [DOWN]);
• Adjust parameters setting (increasing values [UP] or
decreasing values [DOWN]);
• Lock/unlock all the keys by holding both ▲ and ▼ keys
for 5 seconds
ELEC.
HEATING
[ELEC. HEATING] KEY
Press this key to:
• Turn ‘ON’ or turn ‘OFF’ the electrical heater according to
the control program
• Start the electric heater only (if pressed in STANDBY
mode)
• Enable or disable the fan ventilation function (if held
pressed for 5 seconds).
• If pressed at the same time with [ON/OFF] key, adjust
the set parameters.
CLOCK
[CLOCK] KEY
Press this key to:
• Set Clock Time
• Cancel the timer function during the timer ‘ON’ (or timer
‘OFF’) programming
TIMER
[TIMER] KEY
Press this key to Set timer ‘ON’ and timer ‘OFF’.
To deactivate the timer, press the [timer] button and then
the [clock] button.
6.1.1
Parameters/Message display
During running or standby status, press ▲ or ▼ button to check the
relating parameters (see the NAVIGATION DIAGRAM). Press [ON/OFF]
button to exit the checking. If no action to the buttons for 5 seconds, the
controller will exit the parameter checking automatically.
The following signals and message may take place on the display:
• The L0 [CLOCK DISLAY] section shows the current time. When rea-
ding or programming the scheduled timer, the clock display shows the
action time.
Содержание Bollyterm HP
Страница 10: ...10 Cod 1910000001187 nv01 ESEMPI DI CANALIZZAZIONI Italiano...
Страница 22: ...22 Cod 1910000001187 nv01...
Страница 30: ...30 Cod 1910000001187 nv01 English EXAMPLES OF CHANNELING...
Страница 42: ...42 Cod 1910000001187 nv01...
Страница 50: ...50 Cod 1910000001187 nv01 Nederlands VOORBEELDEN VAN KANALISEREN...
Страница 63: ...63 Cod 1910000001187 nv01...