CorDES Proprietary Information
10
Figure 6 Rear View of CDNA-041G
Figure 7 Rear Panel with Port Labels of CDNA-041G
Connection
Name
Connector
Function
AC Power
NEMA5-15P
120-230VAC 50-60Hz Auto-Switching Power inputs
ECU[0] / [1]
Power
L17DM537446
5.25VDC power output to ECUs
PT[0-3]
VHDCI plug, Molex
71425 or equivalent
Serial Plain Text data inputs and outputs for ECUs
CT[0-3]
VHDCI plug, Molex
71425 or equivalent
Serial Cipher Text data inputs and outputs for ECUs
Table 3-2 Rear Panel Connections
4
INSTALLATION
The CDNA-041G is designed to be installed in fixed satellite operation centers that meet the
environmental characteristics specified in the Technical Specifications of this manual.
4.1
Unpacking
The CDNA-041G is shipped in reusable packaging materials. Save these packaging materials
for future use in case you need to ship the CDNA-041G. Save this document along with the
packaging materials for future reference. The CDNA-041G is shipped in a single box which
contains the chassis, faceplate and power cables.