ML20700 PWI Series Mortise Lock
15
Copyright © 2009 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
11. Install Outside Escutcheon Assembly and Mounting Plate:
a. Feed the wires from the outside escutcheon assembly through the opening in the door.
Note: Position ferrite bead from lock body under mounting plate (Fig. 11c).
b. Position and hold the outside escutcheon assembly while securing the mounting plate
to the inside of the door with the hardware provided.
c. Correctly position the lock body harness and the ground wire.
IMPORTANT
-
Required for fire rated doors
: Surface mount screws
required for fire rated doors (Fig. 11b).
IMPORTANT
: Door must remain open during installation. Use door stop.
Position ferrite bead
from lock body
under mounting plate.
Fig. 11c
Mounting Plate
Cables
Mounting Plate
(4) #8 32 X 1-7/8” Flat
Head Machine Screws
Position Ground
Ring Terminal to
bottom right screw
Fig. 11a
Fig. 11b
(2) #8 3/8" Flat Head
Wood Screws or
(2) #8 3/8" Flat Head
Machine Screws
Required for Fire Rate Doors
Inside Face of Door
Outside
Access
Trim
Lock Body Cable
Position Ground
Ring Terminal upright;
then tighten.
Keypad Harness
Keypad Harness
Lock Body Cable