14
Gas Connection
WARNING:
Before starting any work related with gas installation, turn off
gas supply. Risk of explosion.
1.
Connect your appliance to gas cock from the shortest way and in a
manner to prevent any leakage. For safety, the hose used should be maximum
125 cm and minimum 40 cm.
2.
While making gas leakage control; never use lighter, match, glowing
cigarette or similar inflammable matter.
3.
Apply soap bubble on connection point. If any leak/leakage exists,
foaming will occur on soaped region.
4.
If the cooktop is to be mounted on a cabinet or openable drawer, a
heat protection panel having 15 mm minimum opening should be mounted
under the cooktop.
For LPG connection;
For LPG (cylinder) connection, affix metal
clamp on the hose coming from LPG
cylinder. Affix an edge of the hose on hose
inlet connector behind the appliance by
pushing to end through heating the hose
in boiled water. Afterward, bring the clamp
towards end section of the hose and tighten
it with screwdriver. The gasket and hose inlet
connector required for connection is as the
picture shown below.
NOTE:
The regulator to be affixed on LPG cylinder should have 300
mmSS feature.
Main gas pipe
Gasket
Hose inlet connector
Metal clamp
Lpg connection hose
GB