background image

15

18

From the outside only

, apply sealant to the bottom of the enclosure and 50mm up the wall channels and vertical joints as 

shown.

Lubricate the inner top 
and bottom rails using 
the wipe provided.

PN60058

16

Fit the Bump Stops 
to the rail, 

top 

and

 

bottom

 as shown 

on the fixed panel 
side. Tighten the 
screw with a screw 
driver, 

do not

 over 

tighten. Place cover 
cap in the hole. 

17

50mm

Содержание OPTIMA

Страница 1: ...or cables hidden in the wall where you intend to drill Wear safety goggles shoes and appropriate clothing BEFORE INSTALLATION Check that the shower tray is level in all directions The enclosure will not sit correctly on an uneven surface If uneven the wall channels may not fit and the doors may not shut correctly The enclosure should be fitted on tiled walls which are sealed with waterproof grout ...

Страница 2: ...aled right up to the tray edge so that the bottom of the wall channel is sealed Failure to do this will cause water to leak under the wall channel and between the tray and tiles resulting in damp patches on the wall and under the tray 1 a b 1500 PN40272 1700 PN40273 Check contents of pack before installation If anything is missing contact our Customer Careline for assistance CUSTOMER CARELINE 0174...

Страница 3: ...rill 6 5mm holes 30mm deep and insert the wall plugs b Apply sealant to the back of the wall channels c Fix the wall channels to the walls using 8 x 32mm screws and screw caps ø 6 5 mm Inside 32mm a b c a Place the bottom rail onto the tray with its end mouldings inserted into the wall channels b Centre the bottom rail between the wall channels so that there is an equal gap at each end 3 a b X X D...

Страница 4: ...d slide down so they fully slot onto the end mouldings of the bottom rail Inside the enclosure ensure the panels sit in the fixed panel brackets slide the brackets along the rail and position under the panels as shown 6 Position the top rail onto the top of the fixed panels Adjust the position of the fixed panel brackets as required Line up the holes and fix using 2 x 13mm screws 4 Fixed panel bra...

Страница 5: ...ors Push fit magnetic seals PN80564 onto the closing edge of the doors the same side as door handle hole Note Ensure the magnetic seals are positioned as shown Note Wetting the glass with water will help fit the seals PN 40259 Outside face of door Door handle hole PN40259 PN80564 Door handle hole Outside face of door PN80564 PN80564 5 7 Check the door frame is vertical and is centrally positioned ...

Страница 6: ...ails 10 From inside Top of doors Bottom of doors The cam adjusters at the top and bottom of the doors may need adjusting so that the doors slide freely and the magnetic seals meet evenly when the doors are closed a Loosen all 4 cam adjuster screws on each door 1 turn maximum b Turn the cam adjusters by hand or using a 16mm spanner until the doors hang vertically Re tighten the screws do not over t...

Страница 7: ...sh options 12 Push fit all 4 covers PN60250 onto the middle door stops on the top and bottom rails PN60250 13 PN60250 Lubricate the inner top and bottom rails using the wipe provided PN60058 14 Fit the Bump Stops to the rail top and bottom as shown on the fixed panel side Tighten the screw with a screw driver do not over tighten Place cover cap in the hole 15 ...

Страница 8: ... of life This product contains materials such as aluminium and glass which can be recycled Please contact your local authority to find your nearest recycling centre IMPORTANT You must not use the shower for 24 hours after installation of the enclosure DO NOT use bleach scouring powders solvents or other aggressive cleaning agents To clean use warm soapy water and a clean cloth and rinse off Please...

Страница 9: ... between the tray surface and tiles It is important that the tray is sealed right up to the tray edge so that the bottom of the wall channel is sealed Failure to do this will cause water to leak under the wall channel and between the tray and tiles resulting in damp patches on the wall and under the tray 1 a b SIDE PANEL CONTENTS 3 PN3222 10mm 3 PN4748 1500 PN40272 1700 PN40273 Check contents of p...

Страница 10: ... the walls using 8 x 32mm screws and screw caps Inside 32mm a b c a Insert the side panel into the wall channel ensuring that the corner post is the same distance in from the edges of the tray as the wall channels b From inside the enclosure in the positions shown drill through the wall channel into the side panel using a 3mm drill bit do not drill too deep Fix using 3 x 10mm screws and screw caps...

Страница 11: ...l profile Ensure the flipper seal flaps are on the inside of the fixed panels Note Wetting the glass with water will help to fit the seals 7 Position the fixed panels into the corner post and wall channel and slide down so they fully slot onto the end mouldings of the bottom rail Inside the enclosure ensure the panels sits in the fixed panel brackets slide the brackets along the rail and position ...

Страница 12: ...drill through the corner post and wall channel into the fixed panels using a 3mm drill bit do not drill too deep Fix using 6 x 10mm screws and screw caps ø 3 mm From inside 10mm 9 8 Position the top rail onto the top of the fixed panels Adjust the position of the fixed panel brackets as required Line up the holes and fix using 2 x 13mm screws 13mm Inside ...

Страница 13: ...s From inside the enclosure tighten all 4 fixed panel bracket grub screws onto the glass using the allen key do not overtighten Fit the cover caps PN4745 into the holes Push fit flipper seals PN40259 onto the back edge of the doors Ensure the flipper seal flaps are on the outside of the doors Push fit magnetic seals PN80564 onto the closing edge of the doors the same side as door handle hole Note ...

Страница 14: ...adjusters by hand or using a 16mm spanner until the doors hang vertically Re tighten the screws do not over tighten c Push fit all 8 covers onto the doors 13 From inside PN50103 Fit the door handles to the door ensuring the supplied handle washers are used on each side of the glass Chrome finish handle are supplied for all frame finish options 14 Push fit all 4 covers PN60250 onto the middle door ...

Страница 15: ...wall channels and vertical joints as shown Lubricate the inner top and bottom rails using the wipe provided PN60058 16 Fit the Bump Stops to the rail top and bottom as shown on the fixed panel side Tighten the screw with a screw driver do not over tighten Place cover cap in the hole 17 50mm ...

Страница 16: ... which can be recycled Please contact your local authority to find your nearest recycling centre IMPORTANT You must not use the shower for 24 hours after installation of the enclosure DO NOT use bleach scouring powders solvents or other aggressive cleaning agents To clean use warm soapy water and a clean cloth and rinse off Please note There has been a glass coating applied to this product use a s...

Отзывы: