4.2. OPERATIONAL DESCRIPTION
The
JETCLEAN DF
filter is made with a panelled structure in painted steel sheet provided with a suction connector
for the self-supporting arms UNIVERSAL NO-SMOKE or EVOLUTION NO-SMOKE or COBRA (optional).
The polluted air is sucked through the air intake by the vacuum created inside the casing by the centrifugal fan.
STEP
ACTION
A
The air passes through the vertical pre-chamber in which the first mechanical separation of the
particles takes place by decantation.
B
The heavy particles sink to the bottom of the wheeled container.
C
The remaining particles are filtered by the cartridge filter.
D
The finer filter dust settles in the second container.
E
The air filtered in this way passes through the fan and is expelled through a grid located on the
upper wall of the plenum.
WARNING!
The unit is designed for use in vacuum.