Initiating a manual regeneration.
The softener can perform two different types of manual regeneration
either immediate or delayed.
Immediate Regeneration.
To perform an immediate regeneration you need to press and hold the
regeneration button for around five seconds until the cam starts to move and
the egg timer shows on the screen.
Delayed Regeneration.
Quickly press and let go of the regeneration button once. The regeneration
symbol will appear and flash on the display. A single regeneration will start at
the default or pre set regeneration time, if you wish to cancel this delayed
regeneration simply quickly press the regeneration button again an the
symbol will disappear from the display.
Resetting the Valve Programming.
Occasionally it maybe necessary to reset the valve to factory defaults.
The programmed valve type (softener) can be checked by pressing and holding
the SET and DOWN buttons simultaneously for 5 seconds. H0 and a volume is
displayed e.g. H0 100, the valve has been set as a softener. If in doubt contact
your supplier.
To reset the valve: with H0 displayed, press and hold the SET for 5 seconds
The valve type will now be shown e.g. 255, 268. Choose the correct valve (255
or 268) and press the SET button. Three dashes will now show on screen, this is
the volume and should be set accordingly using the up and down arrows set the
amount applicable to your system (see following programming details)
It will now be necessary to reset the time, day, regeneration time and override
days as above.
Standard
Vessel Size
613 1012
817
919 735
1023
835
935 1035
Type
Micro
Coral
Mistral Coral Swan
Mistral
Swan
Swan
Swan
Press
↓
&
■
together H0 appears) then press
■
Select type of valve
255
255
255
255
255
255
255
255
255
Media Volume to program (litres)
4
10
10
15
18
22
25
30
35
Parameter
Time of day (HH:MM)
P1
Set on site
Day of week (DAY)
P2
Set on site
Time of regeneration (HH:MM)
P3
Set on site / Factory set default 2.00am
Calendar override days
740/760
P4
3/14
3/14
3/14
3/14
3/14
3/14
3/14
3/14
3/14
Regen interval if P4 set to 0
(740 ONLY)
P5
Set on site if required
Salt amount (gms)
P6
S
S
S
S
S
S
S
S
S
Capacity (Kg)
740 control
(cannot change)
P7
0.2
0.5
0.5
0.8
0.9
1.1
1.3
1.5
1.8
Capacity (Kg)
760 control
P7
0.2
0.5
0.5
0.7
0.9
1.1
1.3
1.5
1.8
Hardness in ppm CaCO3
P8
Set on site 760 only