Troubleshooting 

 

 

 

 

 

Proble m 

Possible Cause 

Solution 

 

 

 

1. Regenerant Tank Overflow  A) Drain line restricted. 

Check the drain line is not blocked 

 

 

or kinked. 

See also 4 

B) Uncontroller refill flow rate. 

Remove refill flow control to clean 

 

 

ball and seat. 

 

C) Air leak in regenerant line. 

Check all connections in regenerant 

 

 

line for leaks. 

 

D) Drain control clogged with resin  Clean drain control. 

 

or other debris. 

 

 

E) Sinking air check ball (255 only).  Replace air check ball. 

 

F) Incorrect drain control fitted. 

Too small a drain control with a larger 

 

 

injector may reduce the draw rates. 

 

G) Regenerant valve disc 1 being 

Remove obstruction. 

 

held open. 

 

 

H) Valve disc 2 not closed during 

Remove obstruction. 

 

regenerant draw causing a refill. 

 

2. Water flow from drain or 

A) Flapper valve return spring weak.  Replace valve spring. (contact dealer) 

regenerant line when in service.  B) Debris stopping flapper valve from  Remove debris. 

 

closing. 

 

3. Hard water after regeneration  A) Incorrect / failed regeneration. 

Repeat regeneration after checking 

 

 

settings. 

 

B) Leaking external bypass valve. 

Replace bypass (contact dealer) 

 

C) O-Ting around riser damaged. 

Replace O-Ring (contact dealer) 

 

D) Capacity too low due to incorrect  Check settings and adjust if required. 

 

setting. 

 

4. Will not draw regenerant or  A) Low water pressure. 

Fit a pump (contact dealer) 

intermittent or irregular draw.  B) Drin line restricted. 

Check drain line is not blocked or 

 

 

kinked. 

 

C) Inlector plugged. 

Clean injector and screen. 

 

D) Injector defective. 

Replace injector. 

 

E) Flapper 2 &/or 3 not fully closed.  Remove debris, check flapper for 

 

 

closing or replace. (contact dealer) 

 

F) Air check prematurly closed. 

Put control into refill C8, replace 

 

 

or repair air check if needed (contact 

 

 

dealer) 

5. System will not regenerate  A) Power not connected. 

Connect power. 

automatically. 

B) Defective motor. 

Replace motor (contact dealer) 

 

C) Fouled or defective turbine. 

Clean or replace turbine. 

 

D) Defective turbine cable. 

Replace turbine cable. 

 

E) Turbine cable not positioned 

Push sensor into housing fully until 

 

correctly. 

it clicks into place. 

6. System regenerated at the 

A) Settings incorrect. 

Correct settings. 

wrong time. 

 

 

7. No conditioned water after  A) No salt in tank or level too low. 

Add salt to regenerant tank, level 

regeneration. 

 

should always be above the water 

 

 

level. 

 

B) Injector plugged. 

Clean injector and screen. 

 

C) Air check closes prematurely. 

Check connections for air leaks and 

 

 

check air check ball (255) floats. 

 

 

See also 1 e & 4 f. 

8. Backwashes at excessively  A) Incorrect drain controller used. 

Replace with correct size. 

low or high rate. 

B) Debris affecting valve operation.  Remove drain controller and clean 

 

 

volume to correct setting. 

 

Содержание Coral Series

Страница 1: ...Cabinet Water Softener Installation Operating Guide Manual 001 5 ...

Страница 2: ... 1 Outlet 1 Drain Barbed Overflow Barbed Power requirement 240V 12V 50Hz 3 amp plug in transformer supplied Inlet water pressure Min 20 psi Max 120psi Working temperature Max 40 C Protect from frost The softener may or may not be supplied with connection hoses drain hoses or bypass valve sets depending on your supplier these are available to order separately if required from your supplier Planning...

Страница 3: ...ftener overflow and be a minimum of in size A single Check Valve A suitable check valve should be fitted This will usually be in the installation kit that can be ordered separately Check List Before you start the installation make sure that you have all the necessary fittings The purchase of one of our standard installation kits will normally ensure that you have everything that you need for a typ...

Страница 4: ...the Softener tails Normally the Softener tails are in a configuration of three with the centre normally being the waste outlet Waste Pipe Installation Connect the waste pipe to the waste outlet on the Softener and run the hose to either an up stand or outside drain a minimum air gap of 20mm must exist at the end of the drain line Softened water will have no adverse effect on a septic tank Should y...

Страница 5: ... tank You may also at this point put a quantity of salt into the tank Do not allow the salt level in the brine tank to exceed the height of the overflow The amount of salt used will depend on the type and model of Softener you have you should never let the brine tank become completely empty of salt and it is advisable to check the salt levels on a regular basis until a usage pattern has been estab...

Страница 6: ...er waste and power supply Initial Power Up Plug the transformer into the rear of the control panel this is located to the left top corner of the panel if viewing from the front Once the power is connected the display may briefly show the valve type 255 or 268 The valve type will be printed on the side of the valve and should also appear on the delivery documentation On occasions the display may fl...

Страница 7: ...ing and adjust the setting using the up and down arrows to the correct setting see 5 2 On the 740 760 control you have options of S L or H Time when system Regenerates This normally defaults to 2 00am but can easily be changed to a more suitable time if required by pressing the square set button to start the display flashing adjusting the time using the up and down arrows then press the square set...

Страница 8: ...s and hold the regeneration button 4 until the cam starts to rotate when the cam stops moving open the inlet to the softener slowly until it is about a quarter open Water will start flowing into the softener and start purging the air from the softener you will hear the air coming out and eventually water will begin to run steadily from the drain line you can now fully open the inlet valve to the s...

Страница 9: ...reset the valve with H0 displayed press and hold the SET for 5 seconds The valve type will now be shown e g 255 268 Choose the correct valve 255 or 268 and press the SET button Three dashes will now show on screen this is the volume and should be set accordingly using the up and down arrows set the amount applicable to your system see following programming details It will now be necessary to reset...

Страница 10: ...Calc at 13 Calc at 13 Calc at 14 Calc at 17 Calc at 16 Calc at 13 Calc at 13 Calc at 17 Slow Rinse Min C3 40 40 46 43 51 44 46 46 51 Represurise Min C4 3 3 3 3 3 3 3 3 3 Fast Rinse 1 Min C5 2 2 3 3 4 4 3 3 4 Backwash 2 Min C6 1 1 1 1 1 1 1 1 1 Fast Rinse 2 Min C7 1 1 1 1 1 1 1 1 1 Refill Min C8 Calc at 4 Calc at 5 Calc at 7 Calc at 10 Calc at 10 Calc at 12 Calc at 9 Calc at 9 Calc at 10 Standard H...

Страница 11: ... Calc at 16 Calc at 13 Slow Rinse Min C3 44 49 46 43 51 44 46 Represurise Min C4 3 3 3 3 3 3 3 Fast Rinse 1 Min C5 6 6 6 6 6 6 6 Backwash 2 Min C6 1 1 1 1 1 1 1 Fast Rinse 2 Min C7 1 1 1 1 1 1 1 Refill Min C8 Calc at 4 Calc at 5 Calc at 7 Calc at 9 Calc at 10 Calc at 12 Calc at 7 Coral Eco If you have a Coral Eco Water Save fitted with the 762 controller you will need to use the settings below Ves...

Страница 12: ...to home position should be rotating to find home The hour glass should be flashing position on the display indicating the motor is running Camshaft is not turning during Check that the motor is connected ERR 3 display Verify that the motor wire harness is connected to the motor and controller module Verify the optical sensor is connected and in place Verify that the motor gear is engaged with the ...

Страница 13: ...red setting 4 Will not draw regenerant or A Low water pressure Fit a pump contact dealer intermittent or irregular draw B Drin line restricted Check drain line is not blocked or kinked C Inlector plugged Clean injector and screen D Injector defective Replace injector E Flapper 2 or 3 not fully closed Remove debris check flapper for closing or replace contact dealer F Air check prematurly closed Pu...

Страница 14: ... a regeneration to flush valve 11 No water flow display on A Bypass valve in bypass Open bypass metered valves B Meter probe not connected to Connect correctly C Restricted turbine rotation due to Remove turbine and clean Turbine debris in turbine should rotate freely if not replace it 12 Run out of conditioned water A Impropper regeneration Repeat regeneration after checking between regenerations...

Отзывы: