Accelnet & Stepnet Plus Panels STO Manual
16-01338 Rev 00
Page 22 of 34
Copley Controls
8.1.3 STO (Safety) Cable Connector
The STO connector on the
Accelnet & Stepnet Plus Panel
s is a DB-09F type receptacle with selective-gold
plating on the sockets. Threaded bosses accept #4-40 locking screws from the cable connector.
The STO cable plug is an AMPLIMITE HDP-20 that uses crimp and poke contacts with selective-gold plating.
This plug, the contacts, and the STO connector in the drive provide spacings that are greater than the minimum
creepage and clearance distance of 1.24 mm. that is required for fault exclusion when considering the FMEDA
(Failure Modes, Effects, and Diagnostic Analysis) of the system.
Fig. 4
STO Locations
2-Axis:
BE2, BP2
TE2, TP2
1-Axis:
BEL, BPL
TEL