Chapter 4 Menu Setup
21
③
Select “Trace Run…” item to perform the command.
4.5.5 Alarm Setup
Enter Main Menu
→
Dome Function
→
Alarm setup as below:
ALARM SETUP
1 ALARM IN CONDITION: N.O.
2 OUTPUT ENABLE: ON
3 EDIT ALARM
4 ALARM TIMER
0 RETURN
↓
↓
Alarm In Condition
: Set the alarm input type to be Normally Opened (N.O.) or Normally
Closed (N.C.) according to the sensor type.
Output Enable
: If “ON” is selected, the camera will output alarm information on an alarm.
Edit Alarm
: Go to “Edit Alarm” menu as shown below.
EDIT ALARM
1 ALARM IN NO: 7
2 ALARM IN MODE: ON
3 ALARM CALL: PRE56
YES: CALL PRESET 1
NO : CALL PRESET 2
Alarm In NO
: Select alarm input number.
Alarm In Mode
: ON, OFF and Timer are optional.
Alarm Call
: Call the preset you need. When the first alarm input happens, the camera will
automatically switch to this preset to monitor.
Alarm Timer
: Go to “Alarm Timer” menu as shown below.
ALARM TIMER
1 ENABLE: OFF
2 ALM TIME: 00:00
3 DISARM TIME: 00:00
YES: CALL PRESET 1
NO : CALL PRESET 2