Introduction

Welcome

The iLumin Universal Source Controller range from Eaton’s 

Cooper Controls Business has been designed to provide 

maximum flexibility in both installation and operation. Every 

model in the range can accept a variety of industry standard 

control options, from iCANbus to DMX, from ethernet to 

RS-485. Similarly, every model can drive a wide range of lighting 

loads, from incandescents to dimmable fluorescents, from non-

dim apparatus to DALI digital modules.
Much care and attention has been applied to the installation 

and maintenance of the Universal Source Controllers. Each 

model provides clear, logical cable routing and every high 

voltage channel is controlled by an individual, easy to replace 

circuit.

Range Overview

Each model is specified using a part number in the following 

format:

Model Number

Supply 

Voltage

Supply 

Type

Circuits

Feed

Maximum 

Load

SC120-06-UN-1P-

ML-20

120 VAC

1 Phase

6

Main Lugs

16A per 

Channel

SC120-12-UN-1P-

ML-20

12

SC120-06-UN-3P-

ML-20

3 Phase

6

SC120-12-UN-3P-

ML-20

12

SC120-24-UN-3P-

ML-20

24

SC277-06-UN-1P-

ML-20

277 VAC

1 Phase

6

SC277-06-UN-3P-

ML-20

3 Phase

6

SC277-12-UN-3P-

ML-20

12

SC277-24-UN-3P-

ML-20

24

Cabinet Dimensions

Three overall cabinet sizes are available as shown on this and 

the following two pages.

6 Circuit Cabinet

Weight

Packed: 100 lbs (45 Kg)
Unpacked: 88 lbs (40 Kg)

4.13 in. 

 

(105 mm)

37.2 in. (945 

mm)

4.13 in. 

 

(105 mm)

9.78 in.  

(248.5 mm)

4.45 in.  

(113 mm)

7.6 in.  

(193 mm)

20.3 in.  

(517 mm)

Ø 0.89 in.  

(22.5 mm)

0.98 in.  

(25 mm)

4.53 in.  

(115 mm)

1.1 in.  

(28 mm)

1.1 in.  

(28 mm)

1.1 in.  

(28 mm)

13.76 in.  

(349.5 mm)

Knockouts for Supply and 

Load Wiring Only

Knockouts for Low 

Voltage Control 

Wiring Only

Ø 2.42 in.

61.5 mm

SC    120   06    UN   1P   ML    20

Product

SC

 = Source Controller

Supply Voltage

120 =

 120 VAC 

277 =

 277 VAC

Type

UN

 = Universal

Circuit Breaker 

Rating

20

 = 20A

Channels

06, 12, 24

Phase

1P

 = Single Phase

3P

 = Three Phase

Panel Feed

ML

 = Main Lugs

Universal Source Controller

WaveLinx Wired

MN503104ML   

page 3

February 2021

www.cooperlighting.com

Содержание WaveLinx Wired SC-UN

Страница 1: ...ly by a qualified electrician The installation must comply with the appropriate electrical codes and regulations in force in your area The Universal Source Controllers are designed for indoor installa...

Страница 2: ...ibution to Circuits 10 Supply to Internal Circuitry 10 Load Wiring 10 High Voltage Load Wiring 10 Total Load Per Channel 11 Load Wire Gauges 11 Earth Connections 11 High Voltage Load Wiring Flows 11 T...

Страница 3: ...N 1P ML 20 120 VAC 1 Phase 6 Main Lugs 16A per Channel SC120 12 UN 1P ML 20 12 SC120 06 UN 3P ML 20 3 Phase 6 SC120 12 UN 3P ML 20 12 SC120 24 UN 3P ML 20 24 SC277 06 UN 1P ML 20 277 VAC 1 Phase 6 SC2...

Страница 4: ...in 517 mm 27 8 in 707 mm 0 89 in 22 5 mm 0 89 in 22 5 mm 0 98 in 25 mm 0 98 in 25 mm 4 53 in 115 mm 4 53 in 115 mm 1 1 in 28 mm 1 1 in 28 mm 1 1 in 28 mm 1 1 in 28 mm 1 1 in 28 mm 1 1 in 28 mm 13 76...

Страница 5: ...cian The installation must comply with the appropriate electrical codes and regulations in force in your area The Universal Source Controllers are designed for indoor installation and use only The uni...

Страница 6: ...the minimum distances to walls and other equipment shown in the diagrams below are maintained Also ensure that the stated ambient atmosphere requirements are not exceeded Refer to Important points fo...

Страница 7: ...sufficient strength and quality to safely hold the unit ES C 1 2 0 EN T 3 4 5 6 7 8 9 1 2 in 30 mm 1 2 in 30 mm 1 2 in 30 mm 34 8 in 885 mm 54 32 in 1379 8 mm 54 32 in 1379 8 mm 13 4 in 340 mm 13 4 in...

Страница 8: ...lace the two upper and two lower fixing screws Supply Wiring Wiring Flow The Universal Source Controller range has been designed to provide a clear layout and logical progression for all power circuit...

Страница 9: ...uit 277V 2 0 AWG 70 mm2 2 0 AWG 70 mm2 2 AWG 35 mm2 SUPPLY EARTH HOT NEUTRAL Three Phase Supply The Universal Source Controllers are available in three phase supply variants ote N Check the stated vol...

Страница 10: ...uitry The internal power supply that feeds the control panel and associated circuitry can draw its power from any and all phases so that it will still operate in the event that not all supply phases a...

Страница 11: ...uits and couplers Please see the wiring flow diagram on page 8 Typical Load Connections The examples below show some of the most typical loads and the way in which they are connected to a Source Contr...

Страница 12: ...0V 0V 0V 0V For each circuit the low voltage control protocol to be used is selected using the configuration menu on the control panel The programming of the Source Controller channels is covered with...

Страница 13: ...w the control panel accessible either through a removable mini panel or when the complete casing is removed Termination The iCAN DMX and RS 485 are daisy chain protocols that all require termination o...

Страница 14: ...tton for menu navigation Clear Text Display Link and Status Indicators Flashes Regularly to Indicate Correct System Operation When ON indicates that the timeclock function is enabled Where multiple SC...

Страница 15: ...ss the ENT button Depending on the chosen option you will be able to affect outputs as follows All Channels Use the and buttons to adjust the output level 0 to 100 for all channels When the required o...

Страница 16: ...ighlight the option that you wish to alter and then press the button to change its ON OFF status 3 Press the ENT button to save your changes and exit Changing the Operation Menu Password The unit uses...

Отзывы: